2017
DOI: 10.1080/1091367x.2017.1360304
|View full text |Cite
|
Sign up to set email alerts
|

Between-Day Reliability and Usefulness of a Fitness Testing Battery in Youth Sport Athletes: Reference Data for Practitioners

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 31 publications
(30 citation statements)
references
References 31 publications
1
28
1
Order By: Relevance
“…Jump height was measured in centimetres using the Optojump system (Microgate, Bolzano, Italy). Participants were familiar with the CMJ protocol, which has previously been shown to have a typical error of 2.8% and smallest worthwhile change of 3.9% in this population (43). Due to the poor face validity of the CMJ test in a swimming population (23), the swimmers (n=2) did not take part in this test.…”
Section: Study Proceduresmentioning
confidence: 99%
“…Jump height was measured in centimetres using the Optojump system (Microgate, Bolzano, Italy). Participants were familiar with the CMJ protocol, which has previously been shown to have a typical error of 2.8% and smallest worthwhile change of 3.9% in this population (43). Due to the poor face validity of the CMJ test in a swimming population (23), the swimmers (n=2) did not take part in this test.…”
Section: Study Proceduresmentioning
confidence: 99%
“…Fitness testing of athletes is commonplace within amateur and professional sports clubs [ 1 , 2 ], schools [ 3 ] and in the general population [ 4 ]. Strength and conditioning coaches (S&C coach) and sport scientists often administer “fitness testing batteries” for a number of different reasons.…”
Section: Introductionmentioning
confidence: 99%
“…hip height. These heights were chosen because knee (Cronin & Templeton, 2008;Shalfawi, Enoksen, Tønnessen, & Ingebrigtsen, 2012) and hip height (Sawczuk et al, 2017;Yeadon, Kato, & Kerwin, 1999) are commonly employed in literature, allowing for the findings of the present study to be transferred to other research in terms of measurement set-up.…”
Section: Methodsmentioning
confidence: 99%
“…Despite the development of progressive technologies such as dual beam or post-processing timing lights, the use of single beam systems is still widespread (Darrall-Jones, Jones, Roe, & Till, 2016;McFarland, Dawes, Elder, & Lockie, 2016;Roe et al, 2017;Sawczuk et al, 2017;Wong et al, 2017), possibly due to greater availability and lower costs (Haugen & Buchheit, 2016).…”
Section: Introductionmentioning
confidence: 99%