1992
DOI: 10.1080/1047322x.1992.10390161
|View full text |Cite
|
Sign up to set email alerts
|

Bi-Level Passive Monitor Validation: A Reliable Way of Assuring Sampling Accuracy for a Larger Number of Related Chemical Hazards

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2000
2000
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…According to both domestic and international research, passive samplers have been proven as effective as active samplers for organic solvents such as benzene [ 9 , 10 ]. The passive samplers used in this survey have been used worldwide to collect samples of organic solvents in the industrial hygiene sector.…”
Section: Methodsmentioning
confidence: 99%
“…According to both domestic and international research, passive samplers have been proven as effective as active samplers for organic solvents such as benzene [ 9 , 10 ]. The passive samplers used in this survey have been used worldwide to collect samples of organic solvents in the industrial hygiene sector.…”
Section: Methodsmentioning
confidence: 99%
“…Passive samplers have been used for industrial hygiene monitoring for decades, [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28] and their application to the low concentrations of interest for vapor intrusion has been more recently evaluated. [29][30][31][32] International standards are available describing the sampling procedure and the sampler performance assessment.…”
Section: Introductionmentioning
confidence: 99%
“…A bi-level validation of diffusive samplers can be used to ensure accurate determinations of exposure. (6) It is important to note that bi-level validation is only for a series of homologous compounds and should include a full protocol validation on key compounds followed by a partial validation on other members of the series. The concept of 165…”
mentioning
confidence: 99%
“…A bi-level validation of diffusive samplers can be used to ensure accurate determinations of exposure. (6) It is important to note that bi-level validation is only for a series of homologous compounds and should include a full protocol validation on key compounds followed by a partial validation on other members of the series. The concept of 165 bi-level validation has been included in the Comité Européen de Normalisation (CEN) protocol EN 838, (7) American Society for Testing and Materials(ASTM) Standard D6246, (8) and American National Standards Institute (ANSI) Standard 104.…”
mentioning
confidence: 99%