2021
DOI: 10.1016/j.measurement.2020.108263
|View full text |Cite
|
Sign up to set email alerts
|

Bias arising from 222Rn contamination in standardized methods for biobased content determination and a simple removal method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…Hood et al (1989) reported that 222 Rn can be removed during dynamic vacuum recovery of benzene at −78°C. Tudyka et al (2021) described a method of removing 222 Rn using four freezepump-thaw cycles at either −20°C (with a H 2 O ice and NaCl mixture) or −72°C (with a dry ice and ethanol mixture) to bring 222 Rn contamination to the background level.…”
Section: Liquid Scintillation Counters Methodsmentioning
confidence: 99%
“…Hood et al (1989) reported that 222 Rn can be removed during dynamic vacuum recovery of benzene at −78°C. Tudyka et al (2021) described a method of removing 222 Rn using four freezepump-thaw cycles at either −20°C (with a H 2 O ice and NaCl mixture) or −72°C (with a dry ice and ethanol mixture) to bring 222 Rn contamination to the background level.…”
Section: Liquid Scintillation Counters Methodsmentioning
confidence: 99%
“…However, radon ( 222 Rn) inevitably contaminates these samples and can artificially inflate the biocarbon content. To remove 222 Rn from the benzene samples before measurements without waiting 30 days, the resublimation method was used (Tudyka et al 2021). The key point of this method was to test the effectiveness of rapid radon removal.…”
Section: Methodsmentioning
confidence: 99%
“…Benzene was dried by removal of water molecules with sodium metal and atmospheric radon was removed by keeping the benzene sample in a refrigerator for a month, since the half-life of radon is 3.8 days. For the removal of radon, we also followed a re-sublimation process for the two samples (CONT-1 and PCO-2), (Tudyka et al 2021) and involves a mixture of dry ice with ethanol (-78°C) or ice with salt (-21°C). GdS-4327 5.08 ± 0.18 0,07 71.7 ± 3.5 4.9 ± 0.17 4.8 ± 0.17 4.5 ± 0.16 GdA-6615 5.14 ± 0.11 5.0 ± 0.11 4.9 ± 0.10 4.6 ± 0.10 TRa-16679 5.17 ± 0.08 5.0 ± 0.08 4.9 ± 0.08 4.6 ± 0.07 5 rCB-3 Recovered Carbon Black GdS-4394 6.89 ± 0.18 19.31 without TRa-16680 0.02 78.9 ± 1.5 6.7 ± 0.17 6.5 ± 0.17 6.2 ± 0.16 GdA-6616 6.92 ± 0.12 6.7 ± 0.12 6.6 ± 0.11 6.2 ± 0.11 TRa-16680 6.29 ± 0.18 6.1 ± 0.17 6.0 ± 0.17 5.6 ± 0.…”
Section: Benzene Preparation For Lscmentioning