2013
DOI: 10.1016/j.epsr.2013.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Bidirectional impedance-type transformer inrush current limiter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 25 publications
0
7
0
Order By: Relevance
“…In [23][24][25], a current limiter is proposed and then the applicability in limiting inrush current, fault current and the capacitive switching transients is investigated. The topology is a combination of variable DC voltage source, two diodes and two DC reactors in each phase.…”
Section: Research Articlementioning
confidence: 99%
See 2 more Smart Citations
“…In [23][24][25], a current limiter is proposed and then the applicability in limiting inrush current, fault current and the capacitive switching transients is investigated. The topology is a combination of variable DC voltage source, two diodes and two DC reactors in each phase.…”
Section: Research Articlementioning
confidence: 99%
“…In this paper, a six-diode six-reactor TCL for suppressing transformer inrush, motor starting and fault currents in power system is proposed. The proposed circuit topology is an improved variation of DC-reactor type ICLs such as the ICLs presented in [23][24][25], in which the variable DC voltage source is discarded to address the cost, complexity and reliability issues. The proposed TCL can be applied to the primary side of both delta and Y connected transformers.…”
Section: Research Articlementioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, it is important to minimize inrush current in power transformers. There are various efforts for reducing inrush current, including voltage compensation type inrush current limiter [1] using a storable reactor [2] depends on box dimension [3] employing reference modifier to the outer loop or the voltage loop to limit transformers inrush currents [4] installing a transformer differential protection system [5] applying grid-connected photovoltaic system [6] using bidirectional impedance-type inrush current limiter [7]. To reduce inrush current the authors in [8] employed a diode bridge while the others based on refluxing and controlled switching [9].…”
Section: ░ 1 Introductionmentioning
confidence: 99%
“…The bridge-type FCLs with reduced number of controlled devices for inrush current limitation has been given in [21]. In order to reduce the magnitude of inrush current, a bidirectional impedance-type inrush current limiter (BIT-ICL) is proposed in [22]. Application of new control strategy to improve the fault ride through capability of doubly fed induction generator (DFIG) during the symmetrical and asymmetrical grid faults is studied in [23].…”
Section: Introductionmentioning
confidence: 99%