2020
DOI: 10.1021/acs.langmuir.0c01793
|View full text |Cite
|
Sign up to set email alerts
|

Bimetallic Thin-Film Combination of Surface Plasmon Resonance-Based Optical Fiber Cladding with the Polarizing Homodyne Balanced Detection Method and Biomedical Assay Application

Abstract: In this work, we present the optical birefringence properties of the optical fiber cladding that exists as an evanescent field where the refractive index (RI) of the analysis solution is applied for optical sensor aspiration. To enhance the performance of the sensor, we have investigated the sensor with different thicknesses of TiO 2 coating and bimetallic (Ag−Al) film alloy combinations by thermal evaporation coating. We described a special balanced homodyne detection method for the intensity difference chang… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 49 publications
0
4
0
Order By: Relevance
“…Thereafter, it was heated to 70 • C into a solid and then shaped with a paper knife. To fabricate the reaction chamber, the PDMS pattern was bonded with the surface of another glass substrate using an oxygen plasma treatment [34]. The chamber defined the area wherein the chemical reaction associated with the GMPs and the immunoreaction took place.…”
Section: Preparation Of Pdms Chamber On the Glass Substratementioning
confidence: 99%
“…Thereafter, it was heated to 70 • C into a solid and then shaped with a paper knife. To fabricate the reaction chamber, the PDMS pattern was bonded with the surface of another glass substrate using an oxygen plasma treatment [34]. The chamber defined the area wherein the chemical reaction associated with the GMPs and the immunoreaction took place.…”
Section: Preparation Of Pdms Chamber On the Glass Substratementioning
confidence: 99%
“…The birefringence method is based on the interferometer between p-and s-polarization light. Currently, only Huong et al studied the birefringence interferometer biosensor for protein detection based on the SPR technique [110]. MZI-based optical fiber sensors have a series of advantages, such as high sensitivity, good stability, and real-time measurement in vitro.…”
Section: Mzi-based Fiber Biosensorsmentioning
confidence: 99%
“…A PDMS round-shaped mask was placed on the glass substrate after fabrication from mixing the base and the curing agent then heating up to solid 15 . The mask played a role in fitting the light pathway from the optical detection system and limiting chemical loss in the modification.…”
Section: Fabrication Of Pdms Microfluidic Lspr Devicementioning
confidence: 99%