2019
DOI: 10.1002/mp.13388
|View full text |Cite
|
Sign up to set email alerts
|

Bimodal intravascular volumetric imaging combining OCT and MPI

Abstract: Purpose Intravascular optical coherence tomography (IVOCT) is a catheter‐based image modality allowing for high‐resolution imaging of vessels. It is based on a fast sequential acquisition of A‐scans with an axial spatial resolution in the range of 5–10 μm, that is, one order of magnitude higher than in conventional methods like intravascular ultrasound or computed tomography angiography. However, position and orientation of the catheter in patient coordinates cannot be obtained from the IVOCT measurements alon… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 41 publications
0
6
0
Order By: Relevance
“…The illustrated results of the motion artifact profiles underline the need of a catheter tracking over time. In addition to the catheter tracking in 3D [7,10,34,35], the time synchronization of the IVOCT and MPI data leads to an optimized arrangement of OCT A-scans in 3D space. The DICE metrics and stenosis lengths in Tab.…”
Section: Discussionmentioning
confidence: 99%
“…The illustrated results of the motion artifact profiles underline the need of a catheter tracking over time. In addition to the catheter tracking in 3D [7,10,34,35], the time synchronization of the IVOCT and MPI data leads to an optimized arrangement of OCT A-scans in 3D space. The DICE metrics and stenosis lengths in Tab.…”
Section: Discussionmentioning
confidence: 99%
“…We refer to two different methods as IVOCT catheter marker tracking (MT) and input parameter (IP) based volume reconstruction, respectively. For both reconstruction methods, the inner phantom wall is segmented in the IVOCT data using a semi-automatic algorithm [34,35,45]. Especially in the narrowed phantom parts, some manual corrections are applied.…”
Section: Volume Reconstruction Methodsmentioning
confidence: 99%
“…The illustrated results of the motion artifact profiles underline the need of a catheter tracking over time. In addition to the catheter tracking in 3D [7,10,34,35], the time synchronization of the IVOCT and MPI data leads to an optimized arrangement of OCT Ascans in 3D space. The DICE metrics and stenosis lengths in Table 4 emphasize the relevant errors in case of the IP method.…”
Section: Plos Onementioning
confidence: 99%
See 1 more Smart Citation
“…To overcome this challenge, several systems have been developed on a preclinical scale to combine MPI with anatomical imaging modalities like MRI or CT (Franke et al, 2016, 2020; Vogel, Lother, et al, 2014; Vogel, Markert, et al, 2019; Vogel, Rückert, et al, 2014). Due to the fast imaging speed, MPI can also be combined with optical coherence tomography (OCT) to provide intravenous tracer tracking and use this information to incorporate prior knowledge for the OCT image reconstruction (Griese et al, 2019; Latus et al, 2019).…”
Section: Magnetic Particle Imagingmentioning
confidence: 99%