2020
DOI: 10.1016/j.chemosphere.2019.125282
|View full text |Cite
|
Sign up to set email alerts
|

Biocompatible Fe3O4@SiO2-NH2 nanocomposite as a green nanofiller embedded in PES–nanofiltration membrane matrix for salts, heavy metal ion and dye removal: Long–term operation and reusability tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
45
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 146 publications
(48 citation statements)
references
References 23 publications
3
45
0
Order By: Relevance
“…The FT-IR spectra ( Figure 4 ) show the appearance of new bands upon the transition Fe 3 O 4 → Fe 3 O 4 @SiO 2 → Fe 3 O 4 @SiO 2 -NH 2 → Fe 3 O 4 @SiO 2 -NH 2 -EY evidencing the appearance of chemical bonds. In the spectrum of pure Fe 3 O 4 NPs, the strong band at 580 cm −1 is due to Fe-O stretching vibrations in accordance with other authors [ 9 , 11 , 13 ]. This band is observed in the spectra of all the samples.…”
Section: Results and Discursionsupporting
confidence: 91%
See 3 more Smart Citations
“…The FT-IR spectra ( Figure 4 ) show the appearance of new bands upon the transition Fe 3 O 4 → Fe 3 O 4 @SiO 2 → Fe 3 O 4 @SiO 2 -NH 2 → Fe 3 O 4 @SiO 2 -NH 2 -EY evidencing the appearance of chemical bonds. In the spectrum of pure Fe 3 O 4 NPs, the strong band at 580 cm −1 is due to Fe-O stretching vibrations in accordance with other authors [ 9 , 11 , 13 ]. This band is observed in the spectra of all the samples.…”
Section: Results and Discursionsupporting
confidence: 91%
“…This band can be related to the asymmetric stretching vibrations of Si-O-Si. An analogous band was observed and interpreted equally by all the authors studying Fe 3 O 4 @SiO 2 NPs [ 9 , 11 , 13 ]. Symmetric Si-O-Si stretching vibrations were associated in [ 9 ] with the weak band near 808 cm −1 .…”
Section: Results and Discursionsupporting
confidence: 75%
See 2 more Smart Citations
“…Their relatively poor performance in NF and RO systems is attributed by some in the literature to their weak mechanical stability as a consequence of their high amorphous and lower hydrophilic character [20][21][22][23]. As a result, PES membrane utilisation in NF/RO application is highly prone to fouling, which is considered the main limitation to the use of PES membranes in highly pressurised separation processes [23][24][25][26].…”
Section: Introductionmentioning
confidence: 99%