2019
DOI: 10.1149/2.1291915jes
|View full text |Cite
|
Sign up to set email alerts
|

Bionics-Inspired Strong Coupling of Streptococcus-Like NiCo2O4 to Needle-Like MnO2 for Enhanced Electrocatalytic Determination of Glucose

Abstract: Bionics-inspired streptococcus-like NiCo 2 O 4 coated needle-like MnO 2 architecture has been synthesized successfully, denoted as NiCo 2 O 4 -MnO 2 , and the nonenzymatic electrochemical sensor based on NiCo 2 O 4 -MnO 2 exhibits highly sensitive determination toward glucose. MnO 2 nanowires are regarded as effective nucleation sites, which allows uniformly growing of NiCo 2 O 4 as electrocatalytic centers on its surface by a hydrothermal method. The rational combination of streptococcus-like NiCo 2 O 4 and n… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 52 publications
1
4
0
Order By: Relevance
“…8, although the sensitivity for those molecules is lower than that for glucose, these molecules also show linear response by the nonenzymatic biosensor. Similar behavior has also been reported for other metal oxide-based nonenzymatic glucose biosensors 27,28,38,[45][46][47][48][49] . Like most available glucose biosensors, glucose monitor interference by the coexisting biomolecules should be considered in real sample measurements 50 .…”
Section: Lscno Nanofibers Are Responsive To Other Biomoleculessupporting
confidence: 83%
See 1 more Smart Citation
“…8, although the sensitivity for those molecules is lower than that for glucose, these molecules also show linear response by the nonenzymatic biosensor. Similar behavior has also been reported for other metal oxide-based nonenzymatic glucose biosensors 27,28,38,[45][46][47][48][49] . Like most available glucose biosensors, glucose monitor interference by the coexisting biomolecules should be considered in real sample measurements 50 .…”
Section: Lscno Nanofibers Are Responsive To Other Biomoleculessupporting
confidence: 83%
“…Similar behavior has also been reported for other metal oxide-based nonenzymatic glucose biosensors. 27,28,38,45–49 Like most available glucose biosensors, glucose monitor interference by the coexisting biomolecules should be considered in real sample measurements. 50 However, a biosensor that is sensitive to multiple carbohydrates may find application for multiple carbohydrates monitoring in human body fluid or fermentation processes.…”
Section: Resultsmentioning
confidence: 99%
“…Chen et al [ 271 ] synthesized bionics-inspired streptococcus-like mixed oxide NiCo 2 O 4 coated on needle-like MnO 2 architectures. Initially, MnO 2 nanowires were synthesized via a quick precipitation method, while NiCo 2 O 4 were grown on pre-synthesized MnO 2 nanowires via a facile hydrothermal method.…”
Section: Biosensor Applications Of Nano-/micro-structured Nico 2 Omentioning
confidence: 99%
“…20 To overcome these issues, non-enzymatic electrochemical sensor has founded as one of the most convenient methods with lots of merit. 21 Since, the non-enzymatic electro-oxidation performance of glucose depends upon the surface structure and morphology electrode materials. 22 Therefore, various attempts have been made by the researchers and academician to develop the non-enzymatic biosensors from many nano/microstructured materials (Ni, Cu, NiO, CuS, and SnO 2 etc.)…”
mentioning
confidence: 99%