2006
DOI: 10.1161/circulationaha.106.664672
|View full text |Cite
|
Sign up to set email alerts
|

BioSTAR Evaluation STudy (BEST)

Abstract: Background-The use of permanent synthetic implants to close atrial septal defects (ASD) and patent foramen ovale (PFO) has a number of limitations, including late complications and the limiting of transeptal access to the left heart should it be required for the later treatment of acquired heart disease. BioSTAR is a novel, bioabsorbable, atrial septal repair implant. This phase I pilot study evaluates the feasibility, safety, and effectiveness of BioSTAR for the first time in humans. Methods and Results-We co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 131 publications
(19 citation statements)
references
References 34 publications
0
18
0
1
Order By: Relevance
“…The Bio-STAR implant has been available in Europe for patent oval foramen and atrial septal defect closure since 2006, and used in North America primarily for patent oval foramen closure for recurrent stroke prevention [22][23][24]. There is a limited pediatric experience and few studies assessing efficacy in secundum atrial septal defect closure [25].…”
Section: Discussionmentioning
confidence: 99%
“…The Bio-STAR implant has been available in Europe for patent oval foramen and atrial septal defect closure since 2006, and used in North America primarily for patent oval foramen closure for recurrent stroke prevention [22][23][24]. There is a limited pediatric experience and few studies assessing efficacy in secundum atrial septal defect closure [25].…”
Section: Discussionmentioning
confidence: 99%
“…33 As próteses são fabricadas a partir de matriz acelular de colágeno intestinal de porcos montado sobre uma prótese Starflex ® MP35N de duplo disco. O remodelamento é gradual e ocorre em um período de 24 meses, durante o qual o colágeno é absorvido e substituído por tecido próprio do paciente.…”
Section: Tratamento Percutâneo Das Comunicações Interatriaisunclassified
“…Some efforts have been made to develop biodegradable occlusion devices for the closure of ASDs, such as the BioSTAR, BioDisk, and Double BioDisk devices [13,14,15,16,17,18]. The BioSTAR device was the first septal defect occluder to use an absorbable matrix as a barrier membrane, which opened a new era of absorbable occluders.…”
Section: Discussionmentioning
confidence: 99%