Abstract:Blood pressure was measured in both great toes using strain-gauge plethysmography in 100 healthy persons aged 18 to 43 before and during successive compression of the dorsalis pedis artery, the posterior tibial artery, and both arteries at the same time. In 54 (27 percent) of 200 feet, successive compression of the dorsalis pedis and the posterior tibial arteries produced no decrease in pressure in the great toe. In 47 of the feet, toe pressure decreased significantly only after compression of the posterior ti… Show more
“…Even though it is not commonly used at toe level, in this paper we have validated this fi nger device for measuring beat-by-beat blood pressure noninvasively and accurately in the toe. In comparison to established invasive techniques for toe blood pressure, such as cannulation of the dorsalis pedis artery ( 17 ), this device provides a noninvasive technique to measure systolic and diastolic blood pressures at the toe. This technique could potentially be used in patients with severe burns in the upper extremities or in amputees in which arm blood pressure cannot be measured noninvasively.…”
Section: Discussionmentioning
confidence: 99%
“…A Velcro strap that holds the Finometer's air pump was loosely wrapped around the lateral aspect of the foot so as to not obstruct the dorsalis pedis artery, the main blood supply to the foot ( 17,18 ). The fi nger cuff of the Finometer was attached to the second toe of the right foot.…”
The Finometer accurately measures TBP noninvasively with body tilt. Also, muscle oxygenation is highest at small HUT angles and decreases with increased HUT.
“…Even though it is not commonly used at toe level, in this paper we have validated this fi nger device for measuring beat-by-beat blood pressure noninvasively and accurately in the toe. In comparison to established invasive techniques for toe blood pressure, such as cannulation of the dorsalis pedis artery ( 17 ), this device provides a noninvasive technique to measure systolic and diastolic blood pressures at the toe. This technique could potentially be used in patients with severe burns in the upper extremities or in amputees in which arm blood pressure cannot be measured noninvasively.…”
Section: Discussionmentioning
confidence: 99%
“…A Velcro strap that holds the Finometer's air pump was loosely wrapped around the lateral aspect of the foot so as to not obstruct the dorsalis pedis artery, the main blood supply to the foot ( 17,18 ). The fi nger cuff of the Finometer was attached to the second toe of the right foot.…”
The Finometer accurately measures TBP noninvasively with body tilt. Also, muscle oxygenation is highest at small HUT angles and decreases with increased HUT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.