2021
DOI: 10.1016/j.snb.2021.130267
|View full text |Cite
|
Sign up to set email alerts
|

Boosting of NO2 gas sensing performances using GO-PEDOT:PSS nanocomposite chemical interface coated on langasite-based surface acoustic wave sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
26
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 49 publications
(26 citation statements)
references
References 55 publications
0
26
0
Order By: Relevance
“…The choice of techniques and equipment used for the characterization of the SAW-based sensors largely depends on the type of features to be analyzed. The Vector Network Analyser (VNA) is one of the most commonly used measuring equipment [13,31,37,62,86,87,90,[92][93][94] due to its advantages: extremely wide bandwidth, excellent frequency stability, outstanding accuracy of amplitude and phase measurements. The VNA measures complex parameters of single port devices, i.e., the reflection coefficients, or full scattering matrix [S] of two-port transmission type circuits.…”
Section: Saw Sensor Test Methods For Gas Detectionmentioning
confidence: 99%
See 4 more Smart Citations
“…The choice of techniques and equipment used for the characterization of the SAW-based sensors largely depends on the type of features to be analyzed. The Vector Network Analyser (VNA) is one of the most commonly used measuring equipment [13,31,37,62,86,87,90,[92][93][94] due to its advantages: extremely wide bandwidth, excellent frequency stability, outstanding accuracy of amplitude and phase measurements. The VNA measures complex parameters of single port devices, i.e., the reflection coefficients, or full scattering matrix [S] of two-port transmission type circuits.…”
Section: Saw Sensor Test Methods For Gas Detectionmentioning
confidence: 99%
“…If the transfer characteristic does not show a clear maximum, but has an almost flat shape around RCF or it has (multiple) fluctuations, the RCF reading becomes uncertain. Therefore, the actual RCF position can be approximated using certain symmetric analytic functions; as an example, Pasupuleti et al [31] used Gaussian curve fitting to find out the best estimation of the RCF value. Under these conditions, an alternative solution is to observe the phase variation of the transfer coefficient, since it is a measurable quantity even in situations where the |S 21 | modulus is almost constant in the frequency band of interest.…”
Section: Saw Sensor Test Methods For Gas Detectionmentioning
confidence: 99%
See 3 more Smart Citations