Broadband (600–1350 nm) Time-Resolved Diffuse Optical Spectrometer for Clinical Use

Abstract: We report on the design, development, and performance assessment of a portable time resolved system measuring absorption and scattering spectra of highly diffusive media over the 600-1350 nm range. In view of clinical use, two strategies were implemented; the first one equips the system with high responsivity in key tissue absorbing regions, whereas the second one makes the system immune to time drift. The MEDPHOT protocol was used for the performance assessment of the instrument. Finally, the system was enrol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
98
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 86 publications
(104 citation statements)
references
References 46 publications
5
98
1
Order By: Relevance
“…For the linearity measurements, we built a dedicated setup, while for the spectroscopic acquisition we used a setup similar to a state-of-the-art system [21]. Generally speaking, both the experimental setups were based on a pulsed laser as a light source, optical fibers for injecting and collecting the optical pulses to and from the sample, a free-running (i. e. not timegated) Single-Photon Avalanche Diode (SPAD) as a detector and a Time-Correlated Single-Photon Counting (TCSPC) board, as schematically depicted in Figure 2.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…For the linearity measurements, we built a dedicated setup, while for the spectroscopic acquisition we used a setup similar to a state-of-the-art system [21]. Generally speaking, both the experimental setups were based on a pulsed laser as a light source, optical fibers for injecting and collecting the optical pulses to and from the sample, a free-running (i. e. not timegated) Single-Photon Avalanche Diode (SPAD) as a detector and a Time-Correlated Single-Photon Counting (TCSPC) board, as schematically depicted in Figure 2.…”
Section: Methodsmentioning
confidence: 99%
“…Details about the components of the setup are described below and summarized in Table 2. Compared to a state-of-the-art clinical prototype [21] operating with standard 1 mm core glass fibers with NA = 0.37, a theoretical loss in responsivity by a factor of 1900, 470 and 120 is ex- Figure 2 Schematics of the main building blocks composing the setup used for both experiments (linearity and spectroscopy measurements). Details about the main blocks can be found in Table 2.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations