2003
DOI: 10.1103/physrevb.67.035123
|View full text |Cite
|
Sign up to set email alerts
|

Calculation and interpretation ofK-shell x-ray absorption near-edge structure of transition metal oxides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
77
1
1

Year Published

2004
2004
2022
2022

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 110 publications
(84 citation statements)
references
References 22 publications
5
77
1
1
Order By: Relevance
“…In particular, the Ni K-edge absorption is caused by the transition of a 1s electron of nickel from its The interpretation of the Ni K-edge XANES in NiO has been a topic of extensive studies in the past [26,27,28,29,30,31,32,33]. The use of the multiple-scattering approach allowed understanding the origin of main peaks to be due to the scattering by atoms of the first ten coordination shells surrounding the absorber [26,30]. The pre-edge peak A (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…In particular, the Ni K-edge absorption is caused by the transition of a 1s electron of nickel from its The interpretation of the Ni K-edge XANES in NiO has been a topic of extensive studies in the past [26,27,28,29,30,31,32,33]. The use of the multiple-scattering approach allowed understanding the origin of main peaks to be due to the scattering by atoms of the first ten coordination shells surrounding the absorber [26,30]. The pre-edge peak A (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…[18], [19] and [20]. This self-consistent approach (FEFF8) are real space Green's function (RSGF) calculations, which include full multiple scattering (FMS) from atoms within a cluster of a given size, using the spinor relativistic approximation for the solutions of the Dirac equation.…”
Section: Experimental and Theoretical Methodologymentioning
confidence: 99%
“…The experience accumulated through the calculation of the absorption cross section for different systems suggests that the HL ECP offers good performance in the case of metals, while for ionic and covalent systems, the use of DH seems to be more adequate. [17][18][19][20][21] However, the variety of reported results indicates that this choice is material specific and, unfortunately, prevents one from a priori fixing the ECP for each particular case. In this work, we have faced this problem in connection to the case of half-metallic alloys.…”
Section: Introductionmentioning
confidence: 99%