2007
DOI: 10.1051/epjap:2007026
|View full text |Cite
|
Sign up to set email alerts
|

Calculation and measurement of electric field under HVDC transmission lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…The electrical environment under an HVDC transmission line is characterized by several different electrical parameters. These parameters are the electric field, the ion current density, the space charge density, the radio interference, the audible noise, and the magnetic field [2, 3]. The electric field under transmission lines is one of the important parameters for evaluation of electromagnetic environment concerned by people.…”
Section: Introductionmentioning
confidence: 99%
“…The electrical environment under an HVDC transmission line is characterized by several different electrical parameters. These parameters are the electric field, the ion current density, the space charge density, the radio interference, the audible noise, and the magnetic field [2, 3]. The electric field under transmission lines is one of the important parameters for evaluation of electromagnetic environment concerned by people.…”
Section: Introductionmentioning
confidence: 99%
“…The corona discharge is generated in a Wire-Cylinder-Plane (WCP) geometry which consist of an ionized electrode (1), a constantan wire with a diameter of 0.4 mm, attached to a non-ionized metallic cylinder (2) of 40 mm in diameter. The dual electrode (Wire-Cylinder), fixed by two insulating supports (3), is carried at a high voltage Va, provided by the DC-HV source of 0 to ±140 kV, 0.08 A.…”
Section: Methodsmentioning
confidence: 99%
“…Theoretical and experimental research has been executed for numerous a long time in order to understand and control the corona effect. Indeed, many of these studies were aimed at reducing its harmful effects which manifest themselves on high voltage electric power transmission lines [1][2][3][4]. Currently, the corona discharge is at the basis of several industrial applications, such as electrostatic dust precipitation [5], surface treatment [6][7], ozone generation [8][9], painting and spraying powders [10], granular mixtures separation [11][12], etc.…”
Section: Introductionmentioning
confidence: 99%
“…High Voltage Direct Current (HVDC) transmission systems are more favorable than the conventional High Voltage Alternating Current (HVAC) systems because of their economical, technical, and environmental advantages for long distance and bulk power transmission. To date, a ±800 kV HVDC transmission system has been in commercial operation and a ±1000 kV transmission system is being studied on a research basis in China [ 1 ]. The electrical environment under HVDC transmission lines is characterized by several different electrical parameters.…”
Section: Introductionmentioning
confidence: 99%