2010
DOI: 10.1109/tpwrd.2010.2059050
|View full text |Cite
|
Sign up to set email alerts
|

Calculation of Lightning-Induced Voltages on Overhead Distribution Lines Including Insulation Breakdown

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
12
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(14 citation statements)
references
References 18 publications
1
12
0
1
Order By: Relevance
“…The 1.5 factor is an approximation which accounts for the turnup in the insulation volt-time curve, as the induced voltages are assumed to have much shorter duration waveforms than the standard 1.2/50 s test waveform. However, some authors (e.g., [18]) propose that a factor of 1.2 instead of 1.5 would lead to more realistic results. Indeed, the 1.5 factor seems to be derived from the assumption of perfectly conducting soil, which leads to very short waveforms.…”
Section: Discussionmentioning
confidence: 99%
“…The 1.5 factor is an approximation which accounts for the turnup in the insulation volt-time curve, as the induced voltages are assumed to have much shorter duration waveforms than the standard 1.2/50 s test waveform. However, some authors (e.g., [18]) propose that a factor of 1.2 instead of 1.5 would lead to more realistic results. Indeed, the 1.5 factor seems to be derived from the assumption of perfectly conducting soil, which leads to very short waveforms.…”
Section: Discussionmentioning
confidence: 99%
“…Se presentó, por primera vez a nivel mundial, este aporte (Silveira, 2008). Y en (Pérez, 2006) los 3 principales aportes se realizaron en: a) descripción de los diferentes efectos de los parámetros del rayo y de la línea sobre las tensiones inducidas, b) identificación de los parámetros más influyentes en las tensiones inducidas y c) una ecuación sencilla para calcular tensiones inducidas máximas con errores menores que las ecuaciones existentes y así lograr aplicaciones para ingeniería eléctrica (Conti, 2010).…”
Section: Física Y Matemáticas En El Modelo Del Rayounclassified
“…Most voltages induced on a distribution line by flashes that terminate near a line are less than 300 kV [2]. With respect to traditional methodologies for the study of lightning effect on distribution feeders, those are usually carried out by digital simulation, which reproduce the transient overvoltages at the insulators and by using manual processing they are developed [1]- [13].…”
Section: Introductionmentioning
confidence: 99%
“…Lightning is an important disturbing phenomenon for the distribution feeders performance analysis [13]. Studies of lightning protection in power systems are generally carried out by digital simulation [3].…”
Section: Introductionmentioning
confidence: 99%