Calculation of Sparking Potentials of SF6 and SF6-GAS Mixtures in Uniform and Non-Uniform Electric Fields

Abstract: A simple formula is developed to predict the sparking potentials of SF6 and SF6-gas mixture in uniform and non-uniform fields.The formula has been shown to be valid over a very wide range from 1 to 1800 kPa-cm of pressure and electrode gap [1-7, 9-13, 17-19] and it would be useful to put this data in a handy form so that it can be used conveniently in practical problems of engineering interest.There is a definite indication from the published data [5][6][7] that the sparking potential of a mixture is rela… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1982
1982
2020
2020

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The measurements [1][2][3]6] indicate that the breakdown voltage of a mixture containing an electronegative gas is related to its breakdown voltage. The available data also show that any correlation between the mixture proportion and breakdown voltage obtained from measurements at a [4,7]. In the present case the measurements are available in coaxial cylinders only; U is therefore calculated from R.…”
Section: Analysis and Resultsmentioning
confidence: 63%
See 2 more Smart Citations
“…The measurements [1][2][3]6] indicate that the breakdown voltage of a mixture containing an electronegative gas is related to its breakdown voltage. The available data also show that any correlation between the mixture proportion and breakdown voltage obtained from measurements at a [4,7]. In the present case the measurements are available in coaxial cylinders only; U is therefore calculated from R.…”
Section: Analysis and Resultsmentioning
confidence: 63%
“…With some limitations Eq. (1) has however been applied earlier quite successfully in dc and power frequency ac breakdowns [4] over a wide range of pd.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Since the electric field is nonuniform, the multiplication of SF6 pressure and distance between the selected points is calculated within the range of 50 ≤ pd ≤ 1200 for the simulations. Figure 2 shows the breakdown voltages of SF6 gas with respect to the multiplication of pressure and electrode gap in kPa cm [19].…”
Section: Definition Of the Sf6 Gas-insulated Transformer (Git) Modelmentioning
confidence: 99%
“…Figure 2 shows the breakdown voltages of SF6 gas with respect to the multiplication of pressure and electrode gap in kPa cm [19].…”
Section: Definition Of the Sf6 Gas-insulated Transformer (Git) Modelmentioning
confidence: 99%