2009
DOI: 10.1109/tase.2009.2021350
|View full text |Cite
|
Sign up to set email alerts
|

Calibrating an Automatic Zoom Camera With Moving Least Squares

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 35 publications
0
14
0
Order By: Relevance
“…And a large number of studies have already focused on modeling the variations of intrinsic parameters associated with lens settings (Agapito et al, 2001;Alvarez et al, 2012;Burner, 1995;Fraser and Al-Ajlouni, 2006;Fraser et al, 2012;Kim et al, 2010;Li and Lavest, 1996;Sanz-Ablanedo et al, 2012;Sarkis et al, 2007Sarkis et al, , 2009Tarabanis et al, 1992;Wiley and Wong, 1995;Willson, 1994;Wu et al, 2013). On the basis of existing studies, an extended Brown self-calibration model is used in our calibration method:…”
Section: Empirical Zoom/focus Modelsmentioning
confidence: 99%
See 1 more Smart Citation
“…And a large number of studies have already focused on modeling the variations of intrinsic parameters associated with lens settings (Agapito et al, 2001;Alvarez et al, 2012;Burner, 1995;Fraser and Al-Ajlouni, 2006;Fraser et al, 2012;Kim et al, 2010;Li and Lavest, 1996;Sanz-Ablanedo et al, 2012;Sarkis et al, 2007Sarkis et al, , 2009Tarabanis et al, 1992;Wiley and Wong, 1995;Willson, 1994;Wu et al, 2013). On the basis of existing studies, an extended Brown self-calibration model is used in our calibration method:…”
Section: Empirical Zoom/focus Modelsmentioning
confidence: 99%
“…Second, (Sarkis et al, 2009) calibrated zoom lenses by fitting the continuous local functions of intrinsic parameters with respect to zoom and focus settings on the basis of the moving least square scheme. This method first completes separate monofocal calibrations at some scattered zoom and focus points.…”
Section: Introductionmentioning
confidence: 99%
“…Efforts have previously been made in the calibration of various digital-zoom lens devices, such as computer controllable lens systems [18,19], single-lens reflex cameras [16,20], still video cameras [21,22], pan-tilt-zoom (PTZ) systems [23,24], and industrial cameras [25]. As zoom lenses are predominantly used in computer vision, research into their calibration arose from the computer vision community [26].…”
Section: Related Workmentioning
confidence: 99%
“…Sarkis et al [25] introduced a technique for modeling intrinsic parameters as local functions of clustered lens settings. The model was based on the moving least squares scheme.…”
Section: Related Workmentioning
confidence: 99%
“…[20][21][22][23] In 2000, Y-S Chen et al 24 from National Taiwan University proposed a simple and effective method of calibrating electric zoom cameras' internal parameters. In 2001, a laboratory, CVIP at the University of Louisville, calibrated the zoom camera parameters using neural 25 In 2009, M Sarkis et al 26 from Technical University of Munich (Germany) calibrated automatic zoom camera using the least square method. In 2010, the Health Science College of Milwaukee University (USA) and the Broadcasting Institute of Technology of Yonsei University (Korea) jointly corrected the radial distortion of the automatic zoom camera.…”
Section: Introductionmentioning
confidence: 99%