Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments

Abstract: We present a practical implementation of calibration-free wavelength-modulation spectroscopy with second harmonic detection (WMS-2f) for measurements of gas temperature and concentration in harsh environments. The method is applicable to measurements using lasers with synchronous wavelength and intensity modulation (such as injection current-tuned diode lasers). The key factors that enable measurements without the on-site calibration normally associated with WMS are (1) normalization of the WMS-2f signal by th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
274
0
2

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 490 publications
(281 citation statements)
references
References 43 publications
5
274
0
2
Order By: Relevance
“…Recently, several approaches for calibration-free WMS (CF-WMS) have been suggested [19][20][21][22][23][24][25], usually based on normalizing nf-WMS with 1f-WMS signals to account for instrumentation factors and a wavelength dependent laser intensity. CF-WMS systems were successfully employed for temperature and concentration measurements in shock-tubes [26], engines [27], scram-jet combustors in the presence of inhomogeneously distributed temperature and species concentration [28], and in coal-fired high pressure combustion facilities [29].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, several approaches for calibration-free WMS (CF-WMS) have been suggested [19][20][21][22][23][24][25], usually based on normalizing nf-WMS with 1f-WMS signals to account for instrumentation factors and a wavelength dependent laser intensity. CF-WMS systems were successfully employed for temperature and concentration measurements in shock-tubes [26], engines [27], scram-jet combustors in the presence of inhomogeneously distributed temperature and species concentration [28], and in coal-fired high pressure combustion facilities [29].…”
Section: Introductionmentioning
confidence: 99%
“…The optimum laser input signal frequencies and amplitudes for the WMS technique are often stated when the 2f signal is maximized [29][30][31][32]. However, for this system, the optimum (9)…”
Section: Resultsmentioning
confidence: 99%
“…The theoretical signals used to generate the lookup table were generated following the procedures found in [28,29], as further explained here. The pressure, P (Pa), and temperature, T (K), range covered by the table encompasses what is normally observed in the laboratory, and the overall resolution of the table is balanced to offset the interpolation time of a single value.…”
Section: Theoretical Calibrationmentioning
confidence: 99%
“…This generally adds to the bulkiness of the systems, and hence, a small size is hardly achieved with H 2 S TDLAS sensors. The path length can be reduced by using wavelength modulation or balanced detection approaches, which furthermore improve the sensitivity of TDLAS sensors [17][18][19]. Although the detection of H 2 S concentrations of several ppb has been demonstrated by employing integrated cavity output spectroscopy approach (ICOS) [20], such sensitivities are difficult to obtain in field measurements as the robustness of this kind of systems remains limited [21,22].…”
Section: Introductionmentioning
confidence: 99%