2005
DOI: 10.1088/0957-0233/16/5/008
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of a micromachined particle velocity microphone in a standing wave tube using a LDA photon-correlation technique

Abstract: In this paper, a new method of calibrating an acoustic particle velocity sensor using laser Doppler anemometry (LDA) is discussed. The results were compared and were in good agreement with the results obtained by conventional methods, where the sensitivity of the microflown is obtained with the use of a reference microphone and a standing wave tube. The LDA signal generated by the acoustic particle motion was analysed using the photon-correlation method, where the signal is considered to consist of a series of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…Non-ideal behavior, such as damping due to viscous and thermal effects and non-ideal reflection of the rigid termination, can be neglected. 8 The relation between pressure p͑x͒ and particle velocity u͑x͒ at an arbitrary location in the tube is given by…”
Section: Comparison With Standing Wave Tube Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Non-ideal behavior, such as damping due to viscous and thermal effects and non-ideal reflection of the rigid termination, can be neglected. 8 The relation between pressure p͑x͒ and particle velocity u͑x͒ at an arbitrary location in the tube is given by…”
Section: Comparison With Standing Wave Tube Calibrationmentioning
confidence: 99%
“…The solution is to create an environment where the acoustic impedance is known. The calibration technique used so far was based on a standing wave tube, 7,8 which could only be used for low frequencies. Recently a high frequency approach was introduced by Jacobsen and Jaud based on a spherical source.…”
Section: Introductionmentioning
confidence: 99%
“…For a particle velocity sensor there is no straightforward reference sensor available, so a workaround must be used. A method to calibrate the sensor with a reference particle velocity sensor is described in [40], but this requires expensive equipment and a delicate setup. In certain situations there is a well defined relation with sound pressure however, and reference sound pressure sensors are fully available.…”
Section: Measurement Of Sensitivity and Noise Levelmentioning
confidence: 99%
“…The impedance of a piston-on-a-sphere is given by [48,88]: . Although the description of the impedance of the spherical sound source is rather complicated, quantitatively, the outcome is similar to that of a monopole.…”
Section: Broadband Calibrationmentioning
confidence: 99%
“…Laser Doppler anemometers [88] and microphones can be used as reference, of which the latter are more often used because they are generally available in acoustic labs. An example of such an environment is a standing wave tube where plane waves propagate in one dimension below the tube's cut-off frequency [88,89].…”
mentioning