1995
DOI: 10.1109/19.377850
|View full text |Cite
|
Sign up to set email alerts
|

Calibration of RF field strength meters

Abstract: Abstract-An intercomparison of field strength meters was performed during 1991-1993 over the frequency range 100 kHz-1000 MHz and field strength range 1-10 V/m using different calibration techniques. Four field sensors, electric as well as magnetic, have been used. Seven institutes participated in this intercomparison using at least three different calibration methods. A calibration uncertainty of less than 1 dB can be obtained if certain procedures are followed. The results are applicable in the fields of EMC… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1997
1997
2017
2017

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…The SAC has been used previously for the calibration of EM probes. One of the most important works reported consists in the intercomparison between laboratories in seven European countries through the exchange of several probes using at least three different calibration methods [6]. The results show slight deviations between laboratories, mainly due to the influence of positioning the probe.…”
Section: Semi-anechoic Chamber (Sac)mentioning
confidence: 99%
See 3 more Smart Citations
“…The SAC has been used previously for the calibration of EM probes. One of the most important works reported consists in the intercomparison between laboratories in seven European countries through the exchange of several probes using at least three different calibration methods [6]. The results show slight deviations between laboratories, mainly due to the influence of positioning the probe.…”
Section: Semi-anechoic Chamber (Sac)mentioning
confidence: 99%
“…In this paper, an EM probe calibration method is proposed, in the frequency range from 80 MHz to 1 GHz inside a 3-meter SAC, taking into consideration of the recommendations of IEEE 1309 [3] and other publications [4][5][6][7][8][9][10][11]. The E-field strengths were calibrated at 2, 4, 9 and 20 V/m, and the reference probes used were the Multi Axis Monopole Probe (ETS-Lindgren HI-6105) and the Orthogonal Dipole Probe (ETS-Lindgren HI-6053).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations