Optical Diagnostics and Sensing XVIII: Toward Point-of-Care Diagnostics 2018
DOI: 10.1117/12.2289205
|View full text |Cite
|
Sign up to set email alerts
|

CameraHRV: Robust measurement of heart rate variability using a camera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 12 publications
0
4
1
Order By: Relevance
“…The Polar H10 has already been validated by previous researchers (Gilgen-Ammann et al, 2019 ; Speer et al, 2020 ) and has been used by researchers as a standard criterion device for quantifying cardiovascular metrics (Müller et al, 2019 ; Weaver et al, 2019 ). The observed bias for CAMHRV was higher than previous research conducted on CAMHRV which reported 6 ms bias when compared to an FDA-approved pulse oximeter (Pai et al, 2018 ). The larger bias observed in the present study may be attributed to the previous utilization of a pulse oximeter rather than the preferred methodological comparison strategy that uses mECG.…”
Section: Discussioncontrasting
confidence: 79%
“…The Polar H10 has already been validated by previous researchers (Gilgen-Ammann et al, 2019 ; Speer et al, 2020 ) and has been used by researchers as a standard criterion device for quantifying cardiovascular metrics (Müller et al, 2019 ; Weaver et al, 2019 ). The observed bias for CAMHRV was higher than previous research conducted on CAMHRV which reported 6 ms bias when compared to an FDA-approved pulse oximeter (Pai et al, 2018 ). The larger bias observed in the present study may be attributed to the previous utilization of a pulse oximeter rather than the preferred methodological comparison strategy that uses mECG.…”
Section: Discussioncontrasting
confidence: 79%
“…Several studies have demonstrated that the fundamental frequency of the IPPG signal usually equals the actual pulse rate, especially when the motion artifacts are weak (Pai et al 2018, Wu et al 2018. However, as illustrated in figure 5, some motion artifacts result in dominant motional peaks, and the original fundamental frequency of IPPG is weakened to the second or third highest peak.…”
Section: Self-adaptive Selection Of Ippg Signalmentioning
confidence: 97%
“…Noncontact-based methods for extracting hemodynamics using video recording are a more recent development which more fully utilizes the spatial information provided by smartphone imaging. 68 , 72 , 104 , 123 , 124 Two recent works, by Park et al. 72 and He and Wang, 68 used computational techniques to infer higher resolution spectral responses and predict hemoglobin content in tissue using only RGB smartphone image data.…”
Section: Context and Applicationsmentioning
confidence: 99%