Can we improve the detection rate and interobserver agreement in capsule endoscopy?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
29
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(30 citation statements)
references
References 21 publications
1
29
0
Order By: Relevance
“…After participation in a 10-hour expert tutorial there was no improvement of detection rate and agreement with reference standard. 11 …”
Section: Discussionmentioning
confidence: 99%
“…After participation in a 10-hour expert tutorial there was no improvement of detection rate and agreement with reference standard. 11 …”
Section: Discussionmentioning
confidence: 99%
“…The requirements for computational efficiency in such software are increased as a result of the real-time constraints posed by the clinical workflows and the reviewers' reaction times. 4,5,8,17 The process of developing clinically viable VCE localization software is challenging. Algorithms for estimating motion that are used for tracking the capsule endoscope should become more robust so that they can withstand the motility and deformability of the gastrointestinal tract.…”
Section: Technical Challengesmentioning
confidence: 99%
“…1,2,6 Furthermore, the accuracy of VCE is heavily dependent on accurate interpretation that is not influenced by the reviewer's experience. 7,8 Historically, the VCE miss rates for vascular lesions, ulcers and neoplasms were 5.9%, 0.5% and 18.9%, respectively. 9 Computational methods, which are integral to the reviewing software of the VCE devices, could contribute to the reduction of both the time required by the reviewers and errors in human interpretation.…”
Section: Introductionmentioning
confidence: 99%
“…Video speed can be increased, although it appears that the miss rate may increase with greater viewing speeds (and an optimal viewing speed of no more than 15 frames per second has been recommended) although dual or quadruple view may allow quicker reading times without obvious diminution of pathology detection. The QuickView facility on the Medtronic system (other systems have similar softwares) selects 10% (the proportion selected can be altered by the operator) of the most standout images for viewing, and earlier iterations of this software suggest a sensitivity of lesion detection of 89-100% compared to conventional viewing with a significant reduction in reading time (28,29,(31)(32)(33)(34)(35)(36)(37)(38)(39)(40). Some operators use it as a preliminary screen to look for obvious pathology if information is needed quickly.…”
Section: Ce Reading Softwarementioning
confidence: 99%
“…Some operators use it as a preliminary screen to look for obvious pathology if information is needed quickly. The spontaneous blood indicator selects images containing multiple red pixels, potentially useful in detecting bleeding lesions, but has variable reported sensitivities and specificities for detecting potential bleeding lesions or active bleeding of only 26-81% and 33-76% respectively (28,29,(39)(40)(41)(42)(43).…”
Section: Ce Reading Softwarementioning
confidence: 99%