Can X-ray data distinguish bonding effects from vibrational smearing?

Abstract: The frequent practice of combining X-ray and neutron diffraction for distinguishing vibrational smearing from charge deformation due to chemical bonding is neither necessary nor completely satisfactory. The two effects occur principally in distinct regions of real and reciprocal space. They can be distinguished by X-ray data alone provided these extend to reciprocal radii d* > 2 A-1 and provided the refinement program allows explicitly for the bonding deformation. The success of this separation can be tested b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

12
592
2
5

Year Published

1983
1983
2017
2017

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 803 publications
(611 citation statements)
references
References 25 publications
12
592
2
5
Order By: Relevance
“…2). The differences of mean square displacements along interatomic vectors of bonded non-H atoms are <1.0×10 -3 Å 2 for all temperatures, thus satisfying the Hirshfeld's rigid-bond test 32 and warranting the quality of the ADPs obtained. Table 1.…”
Section: Deconvolution Of Thermal Motion From Valence Bonding Densitymentioning
confidence: 53%
“…2). The differences of mean square displacements along interatomic vectors of bonded non-H atoms are <1.0×10 -3 Å 2 for all temperatures, thus satisfying the Hirshfeld's rigid-bond test 32 and warranting the quality of the ADPs obtained. Table 1.…”
Section: Deconvolution Of Thermal Motion From Valence Bonding Densitymentioning
confidence: 53%
“…Initially, only the scale factor was refined, followed by non-hydrogen, the atomic positions and atomic displacement parameters (ADPs) against all reflections. Subsequently, a high-order (sinθ/λ>0.7 Å −1 ) refinement for non-H atoms was performed, aiming at the deconvolution of the ADP's and bonding deformation effects [20]. The ADPs for H atoms were estimated using SHADE server [21].…”
Section: Multipolar Refinementmentioning
confidence: 99%
“…The Hirshfeld rigid bond test [20] was applied to the nonhydrogen atoms joined by the covalent bonds after the final multipolar refinement. For each pair of non-hydrogen atoms, the values of ΔZ AB 2 (differences between the components of the U ij tensor along the bond) do not exceed the acceptable value of 10 −3 Å 2 .…”
Section: Molecular Geometriesmentioning
confidence: 99%
“…Before the introduction of a charge deformation model it was necessary to constrain the vibration parameters of the H atoms (Hirshfeld, 1976). To this end the molecular skeleton (see Fig.…”
Section: Refinementmentioning
confidence: 99%
“…promolecule plus deformation density, was scanned throughout the asymmetric unit for possible negative values and none at all were found. Finally, the refined vibration parameters were tested against the rigid-bond postulate (Hirshfeld, 1976). The r.m.s, difference z z -z 2 (Table 2) (Table lb).…”
Section: Refinementmentioning
confidence: 99%