2000
DOI: 10.1002/(sici)1522-2683(20000501)21:8<1574::aid-elps1574>3.0.co;2-6
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrochromatography for pesticide analysis: Effects of environmental matrices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
1

Year Published

2001
2001
2005
2005

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 16 publications
0
5
1
Order By: Relevance
“…Several techniques have been developed to bring sensitivity into the realm of HPLC. Thus, in order to enhance sensitivity, analyte stacking was investigated using largevolume injections of aqueous samples [9]. However, this technique resulted in CEC column disequilibration and led to a large increase in retention times.…”
Section: Introductioncontrasting
confidence: 67%
See 1 more Smart Citation
“…Several techniques have been developed to bring sensitivity into the realm of HPLC. Thus, in order to enhance sensitivity, analyte stacking was investigated using largevolume injections of aqueous samples [9]. However, this technique resulted in CEC column disequilibration and led to a large increase in retention times.…”
Section: Introductioncontrasting
confidence: 67%
“…However, this technique resulted in CEC column disequilibration and led to a large increase in retention times. Moreover, in an attempt to improve the detection limit, a high-sensitivity zeta cell was also investigated [9,10]. However, as in CE, this sensitivity gain was often achieved at the expense of separation efficiency.…”
Section: Introductionmentioning
confidence: 83%
“…On the other hand, Cooper et al [67] concluded that for the analysis of azoxystrobin (a fungicide) and pirimicarb (an insecticide) it was impossible to achieve LODs by UV detection required for pesticide residue analysis. A decrease of at least two orders of magnitude was considered required.…”
Section: Pesticidesmentioning
confidence: 99%
“…A nonaqueous method with surfactant modifiers was introduced in 1997 by Carabias-Martínez et al [6] for the separation of the following six triazine herbicides: simazine (26), atrazine (27), ametryne (28), propazine (29), prometryne (30), and terbutryne (31). This method was employed for use in two articles [7,8] where the main focus was on sample preconcentration prior to separation, which will be discussed later.…”
Section: Czementioning
confidence: 99%
“…Cooper et al [26] used the idea of a water-rich sample plug to increase sensitivity for an insecticide, primacarb, and a fungicide, azoxystrobin, before separation by CEC. They were able to improve the S/N by fivefold to about 10:1.…”
Section: On-line Trace Enrichmentmentioning
confidence: 99%