1997
DOI: 10.1016/s0021-9673(97)00372-5
|View full text |Cite
|
Sign up to set email alerts
|

Capillary electrophoresis with electrospray mass spectrometry detection for low-molecular-mass compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
30
0

Year Published

1998
1998
2007
2007

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 42 publications
(30 citation statements)
references
References 13 publications
0
30
0
Order By: Relevance
“…Ion trap Sheath liquid a) FASS, field-amplified sample stacking in the presence of siphoning [326] Basic dendrimers CZE Magnetic sector Sheath liquid [327] Low-molecular-mass compounds CZE Single quadrupole Sheath liquid [328] Small carboxylic acids CZE Single quadrupole Sheath liquid [329] a-and b-chains of hemoglobin of a single intact red blood cell CZE TOF In-column electrode [330] Trace impurities of peptides and alkaloids CZE Triple quadrupole Make-up flow [331] Amino acids CZE Single quadrupole Sheath liquid…”
Section: ] Capillary Isotachophoresis Esi-ms (Citp-esi-ms) A)mentioning
confidence: 99%
“…Ion trap Sheath liquid a) FASS, field-amplified sample stacking in the presence of siphoning [326] Basic dendrimers CZE Magnetic sector Sheath liquid [327] Low-molecular-mass compounds CZE Single quadrupole Sheath liquid [328] Small carboxylic acids CZE Single quadrupole Sheath liquid [329] a-and b-chains of hemoglobin of a single intact red blood cell CZE TOF In-column electrode [330] Trace impurities of peptides and alkaloids CZE Triple quadrupole Make-up flow [331] Amino acids CZE Single quadrupole Sheath liquid…”
Section: ] Capillary Isotachophoresis Esi-ms (Citp-esi-ms) A)mentioning
confidence: 99%
“…On the contrary, a sensitivity decrease (factor about 2) was observed in the presence of formic acid. In contrast to ESI, where an acid in the sheath liquid is mandatory to assist positive ionization [56,[59][60][61], the presence of a protic solvent in the sheath liquid appeared sufficient for photoionization.…”
Section: Sheath Liquid Compositionmentioning
confidence: 99%
“…This is related to the ability of CE to separate complex mixtures of analytes while sample consumption is only minor [20]. In addition, high separation efficiency with up to 10 6 theoretical plates allows for rapid separations within a couple of minutes in most cases [21]. High efficiency and mass sensitivity is promoted by the absence of Eddy-diffusion and mass transfer, both factors that contribute to peak broadening in HPLC [19,22].…”
mentioning
confidence: 99%