2013
DOI: 10.1021/ac4009868
|View full text |Cite
|
Sign up to set email alerts
|

Capillary Isoelectric Focusing-Tandem Mass Spectrometry and Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry for Quantitative Proteomic Analysis of Differentiating PC12 Cells By Eight-Plex Isobaric Tags for Relative and Absolute Quantification

Abstract: We report the application of capillary isoelectric focusing for quantitative analysis of a complex proteome. Biological duplicates were generated from PC12 cells at days 0, 3, 7, and 12 following treatment with nerve growth factor. These biological duplicates were digested with trypsin, labeled using eight-plex iTRAQ chemistry, and pooled. The pooled peptides were separated into 25 fractions using reversed-phase liquid chromatography (RPLC). Technical duplicates of each fraction were separated by capillary iso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
30
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(30 citation statements)
references
References 61 publications
0
30
0
Order By: Relevance
“…With n-octyltrimethoxysilane (C 8 -TMOS) and vinylphosphonic acid as functional monomers, a one-step polycondensation and simultaneous "thiol-ene" click chemistry were further used to prepare C 8 /PO(OH) 2 Furthermore, monolithic-based mixed-mode stationary phases have been less reported. Thus, we anticipate that the development of novel mixed-mode monolithic columns will be another hot-spot in the future research.…”
Section: Monolithic-based Mixed-mode Stationary Phasesmentioning
confidence: 99%
See 3 more Smart Citations
“…With n-octyltrimethoxysilane (C 8 -TMOS) and vinylphosphonic acid as functional monomers, a one-step polycondensation and simultaneous "thiol-ene" click chemistry were further used to prepare C 8 /PO(OH) 2 Furthermore, monolithic-based mixed-mode stationary phases have been less reported. Thus, we anticipate that the development of novel mixed-mode monolithic columns will be another hot-spot in the future research.…”
Section: Monolithic-based Mixed-mode Stationary Phasesmentioning
confidence: 99%
“…Up till now, HPLC has become one of the most popular and powerful techniques in separation science, widely used in separation, qualitative and quantitative determination in a variety of fields [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The interface has several advantages, including minimal sample dilution due to the very low sheath flow rate, elimination of mechanical pumps and nebulizing gas, use of a wide range of separation buffers, and stable operation in the nanospray regime. We have applied the electrokinetically pumped sheath flow nanospray interface CE-MS/MS system for shotgun proteomic analysis of the secretome of Mycobacterium marinum [18], a fraction of yeast lysate [19], the E.coli proteome [20-22], picogram amounts of RAW 264.7 cell lysate [23-25], and the PC12 cell lysate [26]. In addition, the system was also applied for top-down intact protein characterization [27], quantitative multiple reaction monitoring (MRM) of peptide abundance [28], and phosphopeptides characterization [29].…”
Section: Introductionmentioning
confidence: 99%