2010
DOI: 10.1590/s1516-18462010005000040
|View full text |Cite
|
Sign up to set email alerts
|

Caracteristicas vocais acústicas de homens com voz e laringe normal

Abstract: RESUMOTema: características vocais acústicas do filtro e das medidas da fonte vocal masculina. Objetivo: realizar uma revisão de literatura descrevendo e discutindo os aspectos que envolvem as características vocais acústicas de homens com laringe normal relacionadas às medidas da fonte e ao filtro vocal. Conclusão: as medidas de Jita, ShdB e NHR tendem a ser maiores nos homens, enquanto a f0, PHR/HNR e o ATRI tendem a ser menores. As espectrografias tendem a apresentar formantes graves, com média de alcance m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0
23

Year Published

2010
2010
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 27 publications
(36 citation statements)
references
References 22 publications
1
12
0
23
Order By: Relevance
“…Jitter values below 0,6 are considered normal and the average of this parameter in the partial laryngectomy group was 11,41, revealing a high value and corroborating a study that reports that in normal individuals the jitter value is small; nevertheless, in the presence of vocal cords lesions there is a higher aperiodicity and jitter values are more elevated 26 . Some authors affirm that this measure's values are higher in cases of vocal cords disorders, such as what happens in individuals submitted to partial laryngectomy of this study 23,27,28 and is correlated to roughness 14,[29][30][31][32] . The statistical analysis of this parameter by the Fisher exact test indicated significance regarding the horizontal axis deviance in the comparison of both groups (p-0,00000074).…”
Section: Resultssupporting
confidence: 58%
See 1 more Smart Citation
“…Jitter values below 0,6 are considered normal and the average of this parameter in the partial laryngectomy group was 11,41, revealing a high value and corroborating a study that reports that in normal individuals the jitter value is small; nevertheless, in the presence of vocal cords lesions there is a higher aperiodicity and jitter values are more elevated 26 . Some authors affirm that this measure's values are higher in cases of vocal cords disorders, such as what happens in individuals submitted to partial laryngectomy of this study 23,27,28 and is correlated to roughness 14,[29][30][31][32] . The statistical analysis of this parameter by the Fisher exact test indicated significance regarding the horizontal axis deviance in the comparison of both groups (p-0,00000074).…”
Section: Resultssupporting
confidence: 58%
“…Studies affirm that the shimmer alters especially in glottic resistance situations or presence of mass lesions, and it is correlated to the presence of noise at emission and breathiness 11,14,31,34 . Shimmer is frequently associated to the noise at emission and, thus, tend to be higher in cases of breathiness 28 . The author affirms that jitter and shimmer values are usually higher in male voices.…”
Section: Discussionmentioning
confidence: 99%
“…They were also advised to avoid collapse of the cheeks during measurement, so as not to raise the pressure of the oral cavity, generated exclusively by contraction of the facial muscles with closure of the glottis. Were performed three maximum, acceptable and reproducible maneuvers (difference of 10%, or less, between the efforts), with rest interval between the efforts of approximately 1 min, with the highest value recorded in mmHg (22) . At the same time, were evaluated the MPT.…”
Section: Methodsmentioning
confidence: 99%
“…O microfone foi posicionado a uma distância de 15 cm 3,[19][20][21] em frente à boca do entrevistado, que estava em pé com os braços estendidos ao longo do corpo. Para a realização das análises perceptivo-auditiva e acústica, as amostras de voz, armazenadas em mini-disc, foram digitalizadas num computador Pentium III e gravadas no formato wave em CD, o que permitiu a análise das medidas relacionadas à frequência fundamental por meio do programa Multi Dimensional Vocal Program da Kay PENTAX (MDVP): frequência fundamental -f0 (Hz); desviopadrão da frequência fundamental -STD (Hz); média da frequência fundamental -Mf0 (Hz); frequência fundamental mais alta -fhi (Hz); frequência fundamental mais baixa -flo (Hz) 3,21,22 . Para a análise vocal acústica dessas medidas, utilizou-se a amostra da vogal /a/ sustentada em altura e intensidade habituais, utilizando-se um tempo mínimo de três segundos, sendo excluído o início e o término da emissão para que o ataque vocal ou possível decréscimo final da intensidade não interferissem na análise 3,21,22 .…”
Section: Apresentação Dos Casosunclassified
“…Os TMF foram cronometrados e os sujeitos eram orientados a, em pé, inspirar pelo nariz e emitir vogais (/a/, /i/, /u/) e os fonemas /s/ e /z/ em tom, intensidade e velocidade habituais, sustentando-os durante o tempo máximo possível durante a mesma expiração 3,21,22 , por três vezes, sendo escolhida a maior sustentação 21,22 . Na avaliação do TMF da contagem numérica, o procedimento foi o mesmo da avaliação dos TMF de vogais e fricativas, solicitando-se que o sujeito realizasse a contagem a partir do numeral um até o final de uma expiração sem inspirar nesse tempo 3 .…”
Section: Apresentação Dos Casosunclassified