Cardiac Conduction Disturbances Following Transapical «medlab-Kt» Aortic Valve Implantation: First Results

Abstract: Aim: to assess cardiac conduction disturbances after transcatheter aortic valve replacement (TAVR) with the “MedLab-KT” device in early postoperative period.Methods. The study comprised 80 patients (mean age 72,4±5,1 years; 42,5% males) undergoing successful TAVR with the “MedLab-KT”. Before operation, all patients were evaluated with 12-lead ECG and 24-hour Holter monitoring, transthoracic and transesophageal echocardiography, computed tomography, coronarography. In 29 (36,3%) patients cardiac conduction abno… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 18 publications
0
2
0
1
Order By: Relevance
“…The potassium level in the blood was in the reference range of 3.5-5.5 mmol/l. The scope of preoperative examination, implantation technique and postoperative management was described in detail above [1,2,7].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The potassium level in the blood was in the reference range of 3.5-5.5 mmol/l. The scope of preoperative examination, implantation technique and postoperative management was described in detail above [1,2,7].…”
Section: Methodsmentioning
confidence: 99%
“…Specific complications of TAP-AVI include atrial fibrillation (AF) [3][4][5] and different conducting system disorders in the form of incomplete and complete left bundle branch block, up to a complete atrioventricular (AV) block, requiring the implantation of a permanent pacemaker [6,7].…”
mentioning
confidence: 99%
“…В последнее десятилетие транскатетерное протезирование аортального клапана (ТПАК) зарекомендовало себя как альтернатива открытого протезирования АК у пациентов с высоким риском периоперационных осложнений [1,2]. К специфическим осложнениям ТПАК относятся нарушения ритма в виде фибрилляции предсердий (ФП) [3][4][5] и различные нарушения в проводящей системе сердца в виде неполных и полных блокад левой ножки пучка Гиса, вплоть до полной атриовентрикулярной (АВ) блокады, требующей имплантации постоянного электрокардиостимулятора [6,7]. Данные по частоте возникновения ФП в раннем послеоперационном периоде после ТАПК отечественного протеза «МедЛаб-КТ» в литературе отсутствуют.…”