Cascaded H-bridge multilevel converter multistring topology for large scale photovoltaic systems

Abstract: Abstract-Large scale grid connected photovoltaic (PV) energy conversion systems have reached the megawatt level. This imposes new challenges on existing grid interface converter topologies and opens new opportunities to be explored. In this paper a new medium voltage multilevel-multistring configuration is introduced based on a three-phase cascaded H-bridge (CHB) converter and multiple string dc-dc converters. The proposed configuration enables a large increase of the total capacity of the PV system, while imp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
76
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 196 publications
(76 citation statements)
references
References 16 publications
0
76
0
Order By: Relevance
“…Various transformer-less and transformer-isolated dc-dc power conversion topologies have been proposed for grid-connected PV applications [4,16,26]. In the proposed topology, ML-DAB is the first power conversion stage that boosts up the dc voltage obtained from the PV array and also In order to synthesize the 5L voltage , switching pulses and resulting voltage waveforms are defined with respect to angular distances (i.e., , ) instead of the duty cycle.…”
Section: Dc-dc Power Conversion Stagementioning
confidence: 99%
“…Various transformer-less and transformer-isolated dc-dc power conversion topologies have been proposed for grid-connected PV applications [4,16,26]. In the proposed topology, ML-DAB is the first power conversion stage that boosts up the dc voltage obtained from the PV array and also In order to synthesize the 5L voltage , switching pulses and resulting voltage waveforms are defined with respect to angular distances (i.e., , ) instead of the duty cycle.…”
Section: Dc-dc Power Conversion Stagementioning
confidence: 99%
“…It has the ability to inherently balance the DC link voltages while also modifying any of those voltages. Such independent control over the DC links allows tracking of the maximum power points associated with multiple PV arrays [17], [18].…”
Section: Capacitor Voltage Balancingmentioning
confidence: 99%
“…The typical inverters used are Neutral Point Clamped (NPC) and Cascade H-Bridge (CHB) [48]. If a dc-dc stage is connected, an isolated 135 converter suites better for CHB as it needs independent dc input for each CHB used [49]. In the case of a NPC, non-isolated converter is connected in a previous stage [50].…”
Section: Introductionmentioning