Cerebrospinal Fluid Viscosity: A Novel Diagnostic Measure for Acute Meningitis

Abstract: The CSF viscosity is a simple and easy method and can be used as an adjunctive measure for the diagnosis of meningitis. With the support of further and larger clinical studies, CSF viscosity may have a role in the discrimination of bacterial versus aseptic meningitis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
15
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(17 citation statements)
references
References 10 publications
2
15
0
Order By: Relevance
“…Figure 4 Measurements of the valve introduced in the emulated CSF with 10% blood at ~ 38 -40 °C shifts operation to a lower R h as expected based on the lower viscosity of the heated in vitro fluid (~ 0.72 mPa·s) relative to that of water at 23 °C (~ 0.936 mPa·s). 27 Figure 4 μm, and r i = 250 μm tested in three different working environments (water, 10% aqueous microparticle suspension, and aCSF). The latter valve displays less variation that is likely owing to its larger size.…”
Section: Basic Hydrodynamic Valve Characteristicsmentioning
confidence: 99%
“…Figure 4 Measurements of the valve introduced in the emulated CSF with 10% blood at ~ 38 -40 °C shifts operation to a lower R h as expected based on the lower viscosity of the heated in vitro fluid (~ 0.72 mPa·s) relative to that of water at 23 °C (~ 0.936 mPa·s). 27 Figure 4 μm, and r i = 250 μm tested in three different working environments (water, 10% aqueous microparticle suspension, and aCSF). The latter valve displays less variation that is likely owing to its larger size.…”
Section: Basic Hydrodynamic Valve Characteristicsmentioning
confidence: 99%
“…This was chosen because dye injected through the cisterna magna enters the PVS nearly 10 times faster than it enters the parenchyma (<5 minutes vs. ~30 mins) 44 , presumably under a single source of difference in uid pressure. The viscosity (0.001 Pa*s) and density (1000 kg/m 3 ) of CSF were taken from experimentally determined values 45,46 .…”
Section: Modeling Choicesmentioning
confidence: 99%
“…The width of the PVS was between 2-10 µm 1,9,78 . The viscosity (0.001 Pa*s) and density (1000 kg/m 3 ) of CSF were taken from experimentally determined values 79,80 .…”
Section: Model Parametersmentioning
confidence: 99%