2012
DOI: 10.1155/2012/913515
|View full text |Cite
|
Sign up to set email alerts
|

Cervical Vestibular-Evoked Myogenic Potentials: Norms and Protocols

Abstract: Vestibular-evoked myogenic potential (VEMP) testing is a vestibular function test used for evaluating saccular and inferior vestibular nerve function. Parameters of VEMP testing include VEMP threshold, latencies of p1 and n1, and p1-n1 interamplitude. Less commonly used parameters were p1-n1 interlatency, interaural difference of p1 and n1 latency, and interaural amplitude difference (IAD) ratio. This paper recommends using air-conducted 500 Hz tone burst auditory stimulation presented monoaurally via an inser… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
41
1
5

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(54 citation statements)
references
References 30 publications
7
41
1
5
Order By: Relevance
“…It is hypothesized that this occurs because stimulation at all frequencies results in shorter cochlear stimulation [6] . The P13 latency duration results in our study agree with those reported in literature [1][2][3] . We obtained the longest latency with the tone burst stimulation, which is also in accordance with literature.…”
Section: Discussionsupporting
confidence: 93%
See 2 more Smart Citations
“…It is hypothesized that this occurs because stimulation at all frequencies results in shorter cochlear stimulation [6] . The P13 latency duration results in our study agree with those reported in literature [1][2][3] . We obtained the longest latency with the tone burst stimulation, which is also in accordance with literature.…”
Section: Discussionsupporting
confidence: 93%
“…A large amount of data has been obtained by changing several parameters, such as electrode positioning, patient position (e.g., supine, sitting), stimulus type (e.g., tone burst, click), and stimulus application (air or bone conduction) [1][2][3][4][5] . Current literature reports a VEMP response rate of 80-100% [2,3] . Our study also obtained a high response rate.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the lower modal age is similar to that found in this study. Vertigo prevalence found in this study is 2.0% and this is low when compared to other studies done in time past [11][12][13]. This low prevalence may be due to lack of awareness by the communities where the hospital is located or patients perhaps deciding to use alternative traditional medication due to the level of growing poverty amongst our people.…”
Section: Discussioncontrasting
confidence: 58%
“…The gold standard vestibular function test is Electronystagmography (ENG) [4]. The caloric test induces vertigo and assesses only the horizontal semicircular canal function [5].…”
Section: Resultsmentioning
confidence: 99%