2011
DOI: 10.1016/j.supflu.2011.05.017
|View full text |Cite
|
Sign up to set email alerts
|

Cetirizine solubility in supercritical CO2 at different pressures and temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 46 publications
(23 citation statements)
references
References 28 publications
1
21
0
1
Order By: Relevance
“…14 Supercritical fluid technologies are being continuously developed in the pharmaceutical industry to obtain ultrapure products and also are popularly favored in drug manufacturing processes because of their abilities to reduce the particle size distribution and control the morphology without contaminating the active ingredient. 15 Generally, experimental techniques are either dynamic or static methods. In previous works, most of the measurements of the solubility of solids in SCCO 2 16−19 and subcritical or supercritical R134a extraction 7,11 have employed dynamic and static methods, respectively.…”
Section: ■ Introductionmentioning
confidence: 99%
“…14 Supercritical fluid technologies are being continuously developed in the pharmaceutical industry to obtain ultrapure products and also are popularly favored in drug manufacturing processes because of their abilities to reduce the particle size distribution and control the morphology without contaminating the active ingredient. 15 Generally, experimental techniques are either dynamic or static methods. In previous works, most of the measurements of the solubility of solids in SCCO 2 16−19 and subcritical or supercritical R134a extraction 7,11 have employed dynamic and static methods, respectively.…”
Section: ■ Introductionmentioning
confidence: 99%
“…This apparatus is equipped with a sapphire window giving the operator the capability of monitoring inside of the equilibrium cell for possible phase transitions. Upon the capability of this apparatus, the solubility of fluvoxamine maleate is measured using a static method coupled with a gravimetric method [29][30][31][32][33][34][35][36] (see Fig. 1).…”
Section: Methodsmentioning
confidence: 99%
“…In brief, MST has presented an empirical model based on the theory of infinitely dilute solutions [33]. An equation that follows a simple relationship for the solubility of solids in SCFs was deduced:…”
Section: Semi-empirical Correlation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this investigation, a home-made apparatus rated for pressures of 60 MPa at 673 K equipped with a sapphire window was used to measure the solubility of model drug using a static method coupled with a gravimetric method [23,24,[33][34][35][36]. The used apparatus in this study was the modified form of its last version used in the previous works [33].…”
Section: Laboratory Apparatusmentioning
confidence: 99%