1996
DOI: 10.1063/1.49402
|View full text |Cite
|
Sign up to set email alerts
|

Challenges in large-area, thin-film CIGS modules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
5
0

Year Published

1996
1996
2010
2010

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 3 publications
1
5
0
Order By: Relevance
“…1a and b). Although the process is used where mechanical patterning is not an alternative, direct benefits have been reported such as reduced interconnect resistivity [9,10]. Other researchers have found that the resistivity of CIGS-based interconnects is higher than direct Mo-ZnO contacts [8].…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation
“…1a and b). Although the process is used where mechanical patterning is not an alternative, direct benefits have been reported such as reduced interconnect resistivity [9,10]. Other researchers have found that the resistivity of CIGS-based interconnects is higher than direct Mo-ZnO contacts [8].…”
Section: Introductionmentioning
confidence: 97%
“…Interconnect resistivity in a thin-film PV module can be evaluated by different structures [11][12][13]. Furthermore, the precision and dimension of the laser beam can aid in reducing the area loss due to interconnect zone width, thereby improving the efficiency of the modules [9,10]. If indeed a reduced interconnect width can be coupled with a lowered interconnect series resistance, this could mean a significant increase in module efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…The model also accounted for interconnect resistance, interconnect area loss and optical loss in the front transparent contact. This approach is described in more detail elsewhere [10,12]. This model was used very effectively to estimate the optimum module segment width, and to examine the sensitivity and impact of sheet resistivity on module segment width.…”
Section: Module Loss Analysismentioning
confidence: 99%
“…This improvement, and the concomitant gain in fill factor would yield efficiencies approaching 14% on modules having a short circuit current and open circuit voltage comparable to the record module. Comparison of curr ent -voltage characteristics of small area devices made using absorber deposition times of 10 and 20 minutes…”
Section: � a () ------------------------------------------" -----mentioning
confidence: 99%
See 1 more Smart Citation