2013
DOI: 10.1167/13.13.28
|View full text |Cite
|
Sign up to set email alerts
|

Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors

Abstract: We determined the degree to which change in visual acuity (VA) correlates with change in optical quality using image-quality (IQ) metrics for both normal and keratoconic wavefront errors (WFEs). VA was recorded for five normal subjects reading simulated, logMAR acuity charts generated from the scaled WFEs of 15 normal and seven keratoconic eyes. We examined the correlations over a large range of acuity loss (up to 11 lines) and a smaller, more clinically relevant range (up to four lines). Nine IQ metrics were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

3
46
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 39 publications
(49 citation statements)
references
References 60 publications
3
46
0
Order By: Relevance
“…The three metrics reported here have previously been found to be well correlated with visual performance in keratoconus. 40 …”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The three metrics reported here have previously been found to be well correlated with visual performance in keratoconus. 40 …”
Section: Resultsmentioning
confidence: 99%
“…30-31 The literature now contains several descriptions of optical quality metrics that examine the interaction of individual terms and the impact on visual performance. 32-40 Three metrics: light in the bucket, visual Strehl ratio and neural sharpness, have been shown to be well-correlated with changes in optical performance in keratoconus. 40 All three are based on retinal image quality and two of the three incorporate neural weighting functions.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…The choice to evaluate the impact in terms of visual image quality was based on evidence in the literature that root mean square (RMS) wavefront error is relatively poorly correlated with visual acuity 12 and that measured change in visual quality metrics (in particular visual Strehl ratio and neural sharpness) are highly correlated to a measured change in visual performance as measured by acuity in the presence of keratoconus (KC) aberrations. 17,18 …”
Section: Introductionmentioning
confidence: 99%