2022
DOI: 10.1111/ggr.12456
|View full text |Cite
|
Sign up to set email alerts
|

Characterisation of Reference Materials forIn SituRb‐SrDating byLA‐ICP‐MS/MS

Abstract: We present Rb and Sr mass fraction and 87Sr/86Sr isotope ratio measurement results for four reference materials (RMs) obtained from the Service d'Analyse des Roches et des Minéraux (SARM), Nancy, France: Mica‐Mg, Mica‐Fe, GL‐O and FK‐N. These four RMs have different chemical compositions spanning the range of those of most K‐bearing feldspars and micas, making them potential calibration materials for in situ Rb‐Sr dating of natural minerals by LA‐ICP‐MS/MS. Selected grains and flakes from the four RMs present … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 67 publications
0
7
0
Order By: Relevance
“…Reference materials were NIST610 as the primary calibration standard and the in-house secondary RM, which are single crystal mica, namely SagaB biotite, Phalaborwa biotite and Harvard 98973 muscovite. In run GÄD08, the pressed mica nanopowder MicaMg 9,26 has been measured in addition. A comprehensive overview of the essential ICP and laser settings used in each session is presented in Tables 1 and 2.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Reference materials were NIST610 as the primary calibration standard and the in-house secondary RM, which are single crystal mica, namely SagaB biotite, Phalaborwa biotite and Harvard 98973 muscovite. In run GÄD08, the pressed mica nanopowder MicaMg 9,26 has been measured in addition. A comprehensive overview of the essential ICP and laser settings used in each session is presented in Tables 1 and 2.…”
Section: Methodsmentioning
confidence: 99%
“…To correct for elemental and mass-dependent isotopic fractionation, reference materials (RM) with a well-known and homogeneous 87 Rb/ 86 Sr and 87 Sr/ 86 Sr distribution are applied. For in situ Rb-Sr dating, NIST 610 glass 25 and MicaMg-NP 9,26 are the most widely used. 15,20,21,27,28 The latter is a nely ground pressed powder of phlogopite from a pyroxenite from southern Madagascar that displays a homogeneous age signal (519.4 ± 6.5 Ma).…”
Section: Single Crystal Mica Reference Materialsmentioning
confidence: 99%
“…Reference values for MicaMg from Jegal et al . (2022) for 87 Rb/ 86 Sr (155.6 ± 7.3) and 87 Sr/ 86 Sr (1.8622 ± 0.0067) were applied to all sample measurements.…”
Section: Methodsmentioning
confidence: 99%
“…The b coefficient was calculated from 88 Sr/ 86 Sr given the conventionally used true value of 8.375209 ( 86 Sr/ 88 Sr = 0.1194, Nier 1938). Reference values for MicaMg from Jegal et al (2022) for 87 Rb/ 86 Sr (155.6 AE 7.3) and 87 Sr/ 86 Sr (1.8622 AE 0.0067) were applied to all sample measurements.…”
Section: Methodsmentioning
confidence: 99%
“…Among metamorphic rock-forming minerals, mica and garnet are perhaps the most popular for dating. In the past 20 years, the 39 Ar-40 Ar radiometric method has been predominantly used to date mica, by opposition to Rb-Sr, until recently not accessible in situ and still hampered by the availability of homogeneous standard materials Jegal et al [2022]. However, in recent years, the addition of a reaction cell between the quadrupoles in the MS device has enabled the use of reacting gases of various reaction affinities with isobaric elements to resolve isobaric interferences at m = 87.…”
Section: Pinning Dates Along the Crystal Growth Historymentioning
confidence: 99%