2022
DOI: 10.1111/jce.15734
|View full text |Cite
|
Sign up to set email alerts
|

Characteristics of pulsed electric field cardiac ablation porcine treatment zones with a focal catheter

Abstract: Objectives Pulsed electric field (PEF) therapies employ punctuated energy delivery to kill cells in a volume of tissue through mechanisms that are not dependent on thermal processes. A key component to successful cardiac ablation procedures is ensuring the generation of transmural, contiguous ablation zones, which requires in‐depth knowledge regarding treatment sizes for a given therapeutic application. Methods In this study, a series of acute treatments were delivered to porcine ventricles, where triphenyl te… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
31
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(34 citation statements)
references
References 42 publications
1
31
0
Order By: Relevance
“…For the highest dose applied, a central area of hemorrhage was systematically observed compatible with previous studies describing capillary endothelium disruption and erythrocyte extravasation. 12 Although applications were not synchronized with the cardiac cycle, no ventricular fibrillation was induced in any of the applications.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For the highest dose applied, a central area of hemorrhage was systematically observed compatible with previous studies describing capillary endothelium disruption and erythrocyte extravasation. 12 Although applications were not synchronized with the cardiac cycle, no ventricular fibrillation was induced in any of the applications.…”
Section: Resultsmentioning
confidence: 99%
“…For the highest dose applied, a central area of hemorrhage was systematically observed compatible with previous studies describing capillary endothelium disruption and erythrocyte extravasation. 12…”
Section: Resultsmentioning
confidence: 99%
“…The estimated study completion date for both trials is April 2023. An interesting study in porcine ventricles pointed out that dose titration results in different lesion depths, e.g., the 25 A setting created the deepest lesion (8.2 mm), 73) which allows dose adaptation for different wall thicknesses of the heart and tailor ablation therapy even for indications beyond PVI. Figures 5 and 6 show the CENTAURI TM generator and a PVI procedure guided by 3D electroanatomical mapping.…”
Section: Pulsed Field Ablation Systemsmentioning
confidence: 99%
“…Recently, a novel PFA system (CENTAURI; Galvanize Therapeutics) was introduced that enables monopolar biphasic PFA with commercially available, contact force-sensing, solid-tip focal ablation catheters their associated 3-dimensional mapping systems. 4 The purpose of this observational study was to prospectively investigate the feasibility and safety of point-by-point PFA-based PVI using the novel PFA system.…”
mentioning
confidence: 99%
“…Focal PFA applications-annotated by 6-mm diameter tags-were delivered with 20% overlap to secure continuous lesion formation (Figure ). 4 Real-time PV electrograms were obtained by the multipolar mapping catheter. After ablation, a left atrial remap was acquired and PVI was reconfirmed after a waiting period of 30 minutes.…”
mentioning