2007
DOI: 10.1016/j.memsci.2007.06.046
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of ion transport in thin films using electrochemical impedance spectroscopyI. Principles and theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
75
0
2

Year Published

2009
2009
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 97 publications
(78 citation statements)
references
References 50 publications
(99 reference statements)
1
75
0
2
Order By: Relevance
“…The value of permeability ω t may then be determined from this resistance, which shows up in EIS spectrum as a plateau at the lowest frequencies [28,30]. Note that this value is an average for the two coupled ions.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The value of permeability ω t may then be determined from this resistance, which shows up in EIS spectrum as a plateau at the lowest frequencies [28,30]. Note that this value is an average for the two coupled ions.…”
Section: Methodsmentioning
confidence: 99%
“…The principles and protocols of the ion transport measurements through the film were fully elaborated in our previous publications [16,28,30]. The measurements may involve two kinds of salts:…”
Section: Electrochemical Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this work, however, there was no defined maximum Z" and thus capacitance was calculated over select frequency ranges representing regions where the given capacitive element dominated, i.e., where the phase angle was closest to −90 • . Further discussion of equivalent electrical circuit modeling for EIS of coatings and thin films can be found in the literature [18,19].…”
Section: Electrochemical Impedance Spectroscopymentioning
confidence: 99%
“…In a first time, this technique was used for the characterization of the impedance behavior of SAM modified gold electrode and for subsequent extraction of useful information from this. In Figure 3 Nyquist impedance plots for Au-electrode and SAM modified electrode at −400 mV dc potentials are presented, where Re(z) is the real part and Im(z) is the imaginary part of the complex impedance Z [35]. The membrane resistance values, R m , were extracted from fitted data (Table 3) which are 8292 and 37120 Ωcm 2 for bare Au-electrode and mixed modified Auelectrode, respectively.…”
Section: Impedance Measurementmentioning
confidence: 99%