IEEE Nuclear Science Symposuim &Amp; Medical Imaging Conference 2010
DOI: 10.1109/nssmic.2010.6036244
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of low energy Lu background on continuous LYSO blocks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 9 publications
1
4
0
Order By: Relevance
“…However, this background radiation spectrum is primarily above 300 keV, and it is not expected to significantly deteriorate the performance of SPECT imaging when using low energy windows. For example, a count rate of 21 cps/cm3 (7% of the total 176 Lu spectra) was obtained for an 80 keV wide window centred at 140 keV [15]. These measurements are compatible with published data from other authors [16,17].…”
Section: Monolithic Lyso Blocksupporting
confidence: 89%
“…However, this background radiation spectrum is primarily above 300 keV, and it is not expected to significantly deteriorate the performance of SPECT imaging when using low energy windows. For example, a count rate of 21 cps/cm3 (7% of the total 176 Lu spectra) was obtained for an 80 keV wide window centred at 140 keV [15]. These measurements are compatible with published data from other authors [16,17].…”
Section: Monolithic Lyso Blocksupporting
confidence: 89%
“…The background map (figure 10(b)) is not uniform. The background events are more prominent at the edges of the scintillator, where the probability that the 176 Lu gamma decays are able to escape the scintillator without interaction is higher (Lois et al 2010). Additionally, a grid pattern is observed.…”
Section: Discussionmentioning
confidence: 97%
“…Dhanasopon et al used thin pixelated LSO (pixel size 2 mm × 2 mm, 3 mm thick) and an H8500 PSPMT to build a miniature gamma-ray camera. Lois et al (2010) coupled a 51 mm × 51 mm × 4 mm continuous LYSO crystal to a Hamamatsu H8500 PSPMT and measured the LYSO background for a 100-180 keV window. They conclude that the LYSO background should not deteriorate the performance of a SPECT system.…”
Section: Introductionmentioning
confidence: 99%
“…2, has dimensions of 23 × 23 × 30 mm 3 and is encapsulated in an aluminium case Table 1: The table summarises the main properties of a traditional NaI:Tl, a LYSO:Ce, and CeBr 3 (LB) crystals. The values regarding the NaI:Tl are taken from [32,33]; the ones for LYSO:Ce are from [29] and [34]; the numbers for CeBr 3 (LB) are as reported in [31]. The estimated total activity of the LYSO:Ce is about forty times higher than that of the CeBr 3 (LB).…”
Section: The Scintillatormentioning
confidence: 99%
“…The table summarises the main properties of a traditional NaI:Tl, a LYSO:Ce, and CeBr 3 (LB) crystals. The values regarding the NaI:Tl are taken from [32,33]; the ones for LYSO:Ce are from [29] and [34]; the numbers for CeBr 3 (LB) are as reported in [31]. The estimated total activity of the LYSO:Ce is about forty times higher than that of the CeBr 3 (LB).…”
Section: Jinst 14 P09017mentioning
confidence: 99%