2017
DOI: 10.9734/acri/2017/36803
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Particulate Matter Collected at Mysore City Roadways in Association with Urban Traffic Condition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Higher wind speeds at this higher altitude enabled representative dilution effects and therefore samples collected from this procedure were subjected to Dynamical Light Scattering (DLS) size characterisation techniques described later. As stipulated by the Bureau of Indian Standard the following points were considered (Kumar, 2021): Maintaining a density difference between the dispersed particles and the dispersing medium. Using established vortexing methods followed by a segregation of over‐sized particles (r>50.25emμm) using standard wet sieving techniques (Fauzie & Venkataramana, 2017; Kumar, 2021; Pecora, 2000). In this instance, the collected soot particles were ultra‐sonicated (Make: SONICS Vibra Cell) in double‐distilled water at a fixed pulse duration of 30 s lasting up to 10 min. …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Higher wind speeds at this higher altitude enabled representative dilution effects and therefore samples collected from this procedure were subjected to Dynamical Light Scattering (DLS) size characterisation techniques described later. As stipulated by the Bureau of Indian Standard the following points were considered (Kumar, 2021): Maintaining a density difference between the dispersed particles and the dispersing medium. Using established vortexing methods followed by a segregation of over‐sized particles (r>50.25emμm) using standard wet sieving techniques (Fauzie & Venkataramana, 2017; Kumar, 2021; Pecora, 2000). In this instance, the collected soot particles were ultra‐sonicated (Make: SONICS Vibra Cell) in double‐distilled water at a fixed pulse duration of 30 s lasting up to 10 min. …”
Section: Methodsmentioning
confidence: 99%
“…ii. Using established vortexing methods followed by a segregation of over-sized particles (r > 5 μm) using standard wet sieving techniques (Fauzie & Venkataramana, 2017;Kumar, 2021;Pecora, 2000). In this instance, the collected soot particles were ultra-sonicated (Make: SONICS Vibra Cell) in double-distilled water at a fixed pulse duration of 30 s lasting up to 10 min.…”
Section: Ascertaining Particle Size Distributionmentioning
confidence: 99%
“…It lies at 12° 18' 25" N latitude and 76° 38' 58" E longitude. The altitude of the city is 765 m above mean sea level (Fauzie and Venkataramana 2017). Five sites were chosen for the air pollutant sampling based on vehicular traffic and street landscape, either street canyon or open landscape.…”
Section: Study Areamentioning