2010
DOI: 10.1080/02786826.2010.486385
|View full text |Cite
|
Sign up to set email alerts
|

Chemical Mass Closure and Chemical Characteristics of Ambient Ultrafine Particles and other PM Fractions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
26
2

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 55 publications
(32 citation statements)
references
References 40 publications
4
26
2
Order By: Relevance
“…The PM samples collected by the silicon grease-coated foils in stages 1-9 of MOUDI (18-0.1 mm) were analyzed gravimetrically but not chemically, because of interference from the grease-coating. The Teflon filters were conditioned for at least 24-h in a temperature and relative humidity controlled room (22 ± 1°C, 40 ± 5% RH) before sampling (Chen et al, 2010). The average mass concentrations of PM 10 and PM 2.5 determined by the MOUDI were in agreement with those obtained from the Dichot, with a relative deviation of < 20% (Chen et al, 2010).…”
Section: Sampling Methods and Analysissupporting
confidence: 69%
See 1 more Smart Citation
“…The PM samples collected by the silicon grease-coated foils in stages 1-9 of MOUDI (18-0.1 mm) were analyzed gravimetrically but not chemically, because of interference from the grease-coating. The Teflon filters were conditioned for at least 24-h in a temperature and relative humidity controlled room (22 ± 1°C, 40 ± 5% RH) before sampling (Chen et al, 2010). The average mass concentrations of PM 10 and PM 2.5 determined by the MOUDI were in agreement with those obtained from the Dichot, with a relative deviation of < 20% (Chen et al, 2010).…”
Section: Sampling Methods and Analysissupporting
confidence: 69%
“…PM 10 , PM 2.5 and PM 0.1 samples were collected by using a MOUDI (Model 110, MSP Corp., MN, USA) and a dichotomous samplers (Model SA-241, Andersen Inc., Georgia, USA) operated at flow rates of 30 and 16.7 L/min (Chen et al, 2010), respectively. The MOUDI sampler has 10 size stages, with the nominal cutoff diameters of 18 (inlet), 10, 5.6, 3.2, 1.8, 1.0, 0.56, 0.32, 0.18, 0.1 and 0.056 mm (Marple et al, 1991).…”
Section: Sampling Methods and Analysismentioning
confidence: 99%
“…Ultrafine particles (UFPs) are recently attracting increasing attention due to their potential effects on human and environmental health (Chen et al, 2010). Their large surface-to-volume ratio and ability to deposit deep in the respiratory tract make UFPs potentially more toxic than their larger counterpart (Nel et al, 2006;Braniš and Větvička, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, another issue associated with PC involves the choice of the charring correction method-transmittance or reflectance. Substantial charring takes place within the filter and so the drop of filter transmittance in the inert mode is larger than the drop of reflectance, which is dominated by charring only of the near-surface organics (Chow et al 2004;Chen et al 2010). Consequently, the PC concentration determined by the TOT (thermal/optical transmittance) method is »15% higher than PC determined by the TOR method.…”
Section: ¡3mentioning
confidence: 88%
“…However, the backup QBQ filter may adsorb less gaseous organic matter than the front quartz filter, especially at low exposure, if the front quartz filter is not in equilibrium with the sample air stream. The front filter would thus deplete the air stream of organic vapors (Kirchstetter et al 2001;Mader and Pankow 2001;Chen et al 2010). As a result, the QBQ OC level is usually lower than a comparable QBT filter for low exposure.…”
Section: ¡2mentioning
confidence: 99%