Chemical state analysis employing sub‐natural linewidth resolution PIXE measurements of Kα diagram lines

Abstract: A high-energy resolution crystal spectrometer in Johansson geometry, which allows energy resolution below the natural linewidth of the Ka diagram lines, was employed in the measurements of proton-induced Ka x-ray emission spectra of titanium and sulfur pure and compound targets. The results demonstrate a clear dependence of the Ka energy shifts on the chemical state of the element in the sample. This dependence permits the chemical state speciation of low-Z elements in an unknown sample by employing high-resol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(8 citation statements)
references
References 21 publications
0
8
0
Order By: Relevance
“…At the Kα-line a small energy shift in dependence of the binding form can be observed when spectrometers with an extremely good angle resolution are used [35].…”
Section: Xrf-analysismentioning
confidence: 99%
“…At the Kα-line a small energy shift in dependence of the binding form can be observed when spectrometers with an extremely good angle resolution are used [35].…”
Section: Xrf-analysismentioning
confidence: 99%
“…[34][35][36][37] These spectrometers were all built in the latter half of the twentieth century and required multi-kW x-ray tubes to achieve reasonable measurement times. More recent laboratory-based work in this energy range has seen an impressive extension to protoninduced x-ray emission analysis, 38,39 with the same Rowlandcircle instrument also seeing important use at a synchrotron endstation. 17,18,40 Here we present technical details and representative results for a dispersive x-ray emission spectrometer designed a) Author to whom correspondence should be addressed: seidler@uw.edu to function particularly well in this 2-2.5 keV energy range and demonstrate measurements on S and P XES both in the laboratory and at a synchrotron endstation.…”
Section: Introductionmentioning
confidence: 99%
“…3 Kavčič et al achieved a subnatural linewidth resolution in their PIXE system by combining a Johansson-type crystal spectrometer and an x-ray charge coupled device ͑CCD͒ camera. 4 They demonstrated the applicability of their system to the chemical state identification of sulfur contained in an aerosol sample.…”
Section: Introductionmentioning
confidence: 98%