2001
DOI: 10.1016/s0021-9673(00)01105-5
|View full text |Cite
|
Sign up to set email alerts
|

Chiroptical detection during liquid chromatography 7

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2001
2001
2013
2013

Publication Types

Select...
6
3
1

Relationship

3
7

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…Chiroptical detection during liquid chromatography was performed using the Jasco CD-1595 detector (Jasco International Co., Ltd., Tokyo, Japan), which provides the differential absorbance Δ A of the CD and the absorbance A of the UV mode simultaneously as a function of time. The analog experimental data were monitored by the two-channel recorder Asea Brown Boveri SE 120 or digitized and processed using the computer program SEPP. , Simultaneous detection of the CD and the UV signals was carried out with a flow-through cell (25 mm) at the single wavelength of 240 nm. The spectra (220−420 nm) were recorded by a stopped-flow method 21 under the same conditions.…”
Section: Methodsmentioning
confidence: 99%
“…Chiroptical detection during liquid chromatography was performed using the Jasco CD-1595 detector (Jasco International Co., Ltd., Tokyo, Japan), which provides the differential absorbance Δ A of the CD and the absorbance A of the UV mode simultaneously as a function of time. The analog experimental data were monitored by the two-channel recorder Asea Brown Boveri SE 120 or digitized and processed using the computer program SEPP. , Simultaneous detection of the CD and the UV signals was carried out with a flow-through cell (25 mm) at the single wavelength of 240 nm. The spectra (220−420 nm) were recorded by a stopped-flow method 21 under the same conditions.…”
Section: Methodsmentioning
confidence: 99%
“…For the racemate, two peaks with equal areas are found (Figure 4). Another sample shows one peak for (S )-carvone in the chromatogram (14); that is, it is enantiomerically pure. t R / min 20.9…”
Section: Separation Of Enantiomers By Chromatographymentioning
confidence: 99%
“…The acquisition of circular dichroism spectra during LC means that racemates can be applied instead of the antipodes, provided an analytical LC separation is accomplished. Advantage of this technique is its ability to determine relative configurations of interconvertible enantiomers [71][72][73].…”
Section: Chiroptical Detectionmentioning
confidence: 99%