2015
DOI: 10.1016/j.trac.2015.04.001
|View full text |Cite
|
Sign up to set email alerts
|

Chromatographic retention indices in identification of chemical compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(33 citation statements)
references
References 48 publications
(71 reference statements)
0
27
0
2
Order By: Relevance
“…Spots on TLC were visualized by UV light (254 nm) and by spraying with 50% (v/v) aqueous H 2 SO 4 followed by heating. Elemental analyses (microanalysis of carbon, hydrogen, and oxygen) were carried out with a Carlo Erba Elemental Analyzer model 1106 (Carlo Erba Strumentazione) as previously described . IR measurements (neat, ATR‐attenuated total reflectance) were carried out using a Thermo Nicolet model 6700 FT‐IR instrument.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Spots on TLC were visualized by UV light (254 nm) and by spraying with 50% (v/v) aqueous H 2 SO 4 followed by heating. Elemental analyses (microanalysis of carbon, hydrogen, and oxygen) were carried out with a Carlo Erba Elemental Analyzer model 1106 (Carlo Erba Strumentazione) as previously described . IR measurements (neat, ATR‐attenuated total reflectance) were carried out using a Thermo Nicolet model 6700 FT‐IR instrument.…”
Section: Methodsmentioning
confidence: 99%
“…(6), 134 (7), 133 (15), 132 (15), 131(49), 122(5), 121(52), 115 (5) (11), 70(6), 69(13), 67(13), 66(10), 65(11), 63(9), 60(6), 57(39), 56(40), 55(16), 53(7), 51 (20), 44(14), 43(16), 42(13), 41(22), 39 (21). ], 163 (7), 149 (21), 148(8), 147(10), 137(5), 135(29), 133(11), 131 (7), 121(10), 105 (7), 103 (11), 91 (15), 79 (6), 78(6), 77 (15), 71(21), 65(9), 55(5), 51 (7), 43(50), 41 (18), 39 (12). (9), 91 (7), 77 (7), 71 (8), 57(6), 55 (11), 43 (13), 41 (15).…”
Section: Nmr Measurementsunclassified
“…Retention index (RI) was calculated as follows (Babushok, ): Inormalx= 100n+100tnormalx tnormalntn+1 tnormaln where, I x is the retention index of compound “X”; t n is the retention time of reference n‐alkane comes before compound “X”; t n + 1 is the retention time of reference n‐alkane comes after compound “X”; and t x is the adjusted retention time of compound c.”…”
Section: Methodsmentioning
confidence: 99%
“…Comparing the known RIs from a retention-data library with measured values is the standard approach to identification. [9] …”
Section: Original Articlementioning
confidence: 99%