2011
DOI: 10.1016/j.actbio.2010.07.030
|View full text |Cite
|
Sign up to set email alerts
|

Ciprofloxacin-modified electrosynthesized hydrogel coatings to prevent titanium-implant-associated infections

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
67
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 92 publications
(67 citation statements)
references
References 50 publications
0
67
0
Order By: Relevance
“…This macroporous titanium is characterized by multiple layers of hexagonal pores with a 640 lm diameter, 8 macroporosity that facilitates cell migration and bone deposition. 9 It has been shown that porous titanium implants can be enriched, either directly [10][11][12] or by association with biocompatible hydrogels, [13][14][15][16] with antibiotics, 14 VEGF, 15 and FGF-2. 16 To improve implant osseointegration, osteogenic factors can be used for implant enrichment.…”
Section: Introductionmentioning
confidence: 99%
“…This macroporous titanium is characterized by multiple layers of hexagonal pores with a 640 lm diameter, 8 macroporosity that facilitates cell migration and bone deposition. 9 It has been shown that porous titanium implants can be enriched, either directly [10][11][12] or by association with biocompatible hydrogels, [13][14][15][16] with antibiotics, 14 VEGF, 15 and FGF-2. 16 To improve implant osseointegration, osteogenic factors can be used for implant enrichment.…”
Section: Introductionmentioning
confidence: 99%
“…The PHEMA C 1s fitting gave the functional group ratios similar to those reported in literature ( compared to 2:1:1:1:1). [33] The variation between the experimental and literature ratios could be attributed to the surface not being totally covered by the grafted polymer. PEGgrafted surfaces also exhibited the functionalities expected (-CHx, -COC, and -COH).…”
Section: Characterization Of Surface Chemistriesmentioning
confidence: 97%
“…The experimental spectra were fitted using Gaussian-Lorentzian peaks (85:15 ratio), with each having the same full width at half maximum as detailed by previous fitting models in literature. [33,34] Surface wettability was determined using contact angle analysis by averaging measured contact angles of 20 μL water droplets, distributed randomly across the test surface and utilizing image analysis software ImageJ, Version 1.47.…”
Section: Surface Characterization Techniquesmentioning
confidence: 99%
“…[54][55][56] Hydrogel coatings containing the antibiotic ciprofloxacin are being developed to prevent implant-associated infections in titanium devices. 57 Finally, several coatings that elute drugs, biological factors, and minerals have been investigated with the goal of improving the biological response to growth. PTH-and bisphosphonate-coated stainless steel screws increased pullout strength and energy as well as fixation.…”
Section: Applications Of Biomaterials To Plate and Screw Fixationmentioning
confidence: 99%