2023
DOI: 10.1016/j.pdpdt.2023.103334
|View full text |Cite
|
Sign up to set email alerts
|

Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(4 citation statements)
references
References 226 publications
0
4
0
Order By: Relevance
“…To gain a more detailed understanding of corneal changes and complications following cataract surgery in uveitis patients, we recognize the potential value of incorporating advanced imaging technology in future studies. Specifically, the use of anterior segment swept-source optical coherence tomography (AS-OCT) could provide invaluable insights into the structural changes and pathologies affecting the cornea after surgery [21].…”
Section: Resultsmentioning
confidence: 99%
“…To gain a more detailed understanding of corneal changes and complications following cataract surgery in uveitis patients, we recognize the potential value of incorporating advanced imaging technology in future studies. Specifically, the use of anterior segment swept-source optical coherence tomography (AS-OCT) could provide invaluable insights into the structural changes and pathologies affecting the cornea after surgery [21].…”
Section: Resultsmentioning
confidence: 99%
“…Compared to spectral domain OCT (SD-OCT), SS-OCT achieves greater penetration, allowing better observation of tissue structure. In addition, it signi cantly improves the image acquisition speed, and further improves the axial resolution, scanning range and depth [39,40]. Thus, our study aimed to investigate the differences in AC and angle characteristics among hyperopic, emmetropic, and myopic children using SS-OCT.…”
Section: Introductionmentioning
confidence: 99%
“…While some studies suggest that cycloplegia can alter corneal curvature, anterior chamber depth, and axial length in normal eyes, others report no significant changes (15,16). Given the distinct corneal biomechanics and morphology in keratoconus, cycloplegia's effects might differ significantly from those in normal eyes (17,18). This study aims to conduct a comparative analysis of ocular biometric parameters in individuals with and without keratoconus, both pre-and post-cycloplegia (19).…”
Section: Introductionmentioning
confidence: 99%