2020
DOI: 10.1101/2020.05.12.20095638
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Clinical assessment and validation of a rapid and sensitive SARS-CoV-2 test using reverse-transcription loop-mediated isothermal amplification

Abstract: Amid the enduring COVID-19 pandemic, there is an urgent need for expanded access to rapid and sensitive SARS-CoV-2 testing worldwide. Here we present a simple clinical workflow that uses a sensitive and highly specific colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) to detect SARS-CoV-2 and takes forty minutes from sample collection to result. This test requires no specialized equipment and costs a few dollars per sample. Nasopharyngeal samples collected in saline were added… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
24
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(25 citation statements)
references
References 9 publications
1
24
0
Order By: Relevance
“…The current sample collection methods used for SARS-CoV-2 testing require swabs to be placed in 2 mL to 3 mL of commercial collection media, such as Quest Diagnostics Viral Collection Media (VCM) ( 7 ). This method presents a serious challenge for RT-LAMP-based detection, as very little (no more than 1 µL) can be used in a 25-µL reaction, due to the presence of dyes and buffers in the VCM that would prevent visualization of a pH shift in a positive reaction ( 8 ). Other collection media, such as 0.9% saline, have less of an inhibitory effect.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The current sample collection methods used for SARS-CoV-2 testing require swabs to be placed in 2 mL to 3 mL of commercial collection media, such as Quest Diagnostics Viral Collection Media (VCM) ( 7 ). This method presents a serious challenge for RT-LAMP-based detection, as very little (no more than 1 µL) can be used in a 25-µL reaction, due to the presence of dyes and buffers in the VCM that would prevent visualization of a pH shift in a positive reaction ( 8 ). Other collection media, such as 0.9% saline, have less of an inhibitory effect.…”
Section: Resultsmentioning
confidence: 99%
“…Glass milk purification increases this sensitivity at least 10-fold. Furthermore, the specificity was found to be 100%, with no false positives reported (8).…”
Section: Significancementioning
confidence: 86%
See 3 more Smart Citations