Clinical impact of different cut-off values in high-resolution manometry systems on diagnosing esophageal motility disorders

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(23 citation statements)
references
References 8 publications
0
23
0
Order By: Relevance
“…Second, only the Unisensor catheter (Starlet) was used in this study. Unisensor and Manoscan TM (Medtronic, Minneapolis, MN, USA) catheters are available in the HRM system, and each catheter has different cutoff values for the Chicago classifications [17, 19]. In our study, however, a comparison of the parameters for both catheter types resulted in no difference in esophageal manometry diagnoses.…”
Section: Discussion/conclusionmentioning
confidence: 62%
See 1 more Smart Citation
“…Second, only the Unisensor catheter (Starlet) was used in this study. Unisensor and Manoscan TM (Medtronic, Minneapolis, MN, USA) catheters are available in the HRM system, and each catheter has different cutoff values for the Chicago classifications [17, 19]. In our study, however, a comparison of the parameters for both catheter types resulted in no difference in esophageal manometry diagnoses.…”
Section: Discussion/conclusionmentioning
confidence: 62%
“…Other esophageal manometry diagnoses were also evaluated, with the following cut-off values: Contractile vigor was assessed using the DCI (a contraction with a DCI <500 mm Hg-s-cm was failed, a DCI >500 but <1,000 mm Hg-s-cm was weak, and a hypercontractile swallow was defined as a DCI ≥10,000 mm Hg-s-cm). A premature contraction was defined as the presence of a DL <4.5 s [19].…”
Section: Methodsmentioning
confidence: 99%
“…Subsequent investigations using the Sandhill‐Unisensor solid‐state pressure sensor system, 10,11 and Laborie‐MMS‐Unisensor solid‐state pressure system identified similar or lower cut‐offs for the DCI 95th percentile, even when other pressure cut‐offs (eg, the 4 s‐Integrated Relaxation Pressure) were higher for the MMS system 12 . A Japanese study using the Starlet system coupled with Unisensor catheter showed higher DCI values compared to the ManoScan system, but again the highest individual value did not exceed 8000 mmHg · s · cm 13 . Therefore, the 8000 mmHg · s · cm threshold was retained for all manometry systems in the CCv4.0.…”
Section: Resultsmentioning
confidence: 92%
“…12 A Japanese study using the Starlet system coupled with Unisensor catheter showed higher DCI values compared to the ManoScan system, but again the highest individual value did not exceed 8000 mmHg•s•cm. 13 Therefore, the 8000 mmHg•s•cm threshold was retained for all manometry systems in the CCv4.0.…”
Section: Key Pointsmentioning
confidence: 99%
“…However, in the early recovery phase, there is a demand for recommending HRM, in consideration of the safety of medical staff and patients. (1)(2)(3)(4) Based on the available evidence, we are proposing the following statements regarding HRM in consideration of the current situation of COVID-19.…”
mentioning
confidence: 99%