2021
DOI: 10.1177/15910199211068668
|View full text |Cite
|
Sign up to set email alerts
|

Clinical impact of Sim & Size® simulation software in the treatment of patients with cerebral aneurysms with flow-diverter Pipeline stents

Abstract: Objectives This study evaluated the clinical impact of the Sim&Size® simulation software on the endovascular treatment with flow-diverter stents of patients with unruptured saccular intracranial aneurysms. Methods This monocentric retrospective study evaluated a cohort of patients treated with flow-divert stents between June 1, 2014, and December 31, 2019, for cerebral aneurysms. Patients belonged to two groups, patients treated with and without the Sim&Size® simulation software. Univariate, bivariate,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 17 publications
0
3
0
1
Order By: Relevance
“…To facilitate stent selection and improve the intervention process, an increasing number of virtual stent software programs have been developed, 13 , 14 , 20 and several studies have found that using these software may decrease the stent size or number. 16 , 17 The association between PED size and patient outcome remains unclear, however.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…To facilitate stent selection and improve the intervention process, an increasing number of virtual stent software programs have been developed, 13 , 14 , 20 and several studies have found that using these software may decrease the stent size or number. 16 , 17 The association between PED size and patient outcome remains unclear, however.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, as previously reported, a longer PED may also increase the risk of arterial side branch and perforator occlusion. 13 , 15 , 17 , 20 From this aspect, virtual stent software 16 , 17 should be encouraged given that they may provide distinct advantages in PED length selection and deployment. According to the results of this study, it is recommended that the DL could be as small as possible yet at least greater than 0 mm (this means that the length of the stent is usually larger than the neck of the aneurysm and covers the proximal and distal ends of the aneurysm by at least 5 mm).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…29, N3, 2023 покриттям [7,8] і доопераційне моделювання на підставі 3D-RA-протоколу ангіографії. Доопераційне моделювання дає змогу обрати найоптимальніший за розміром ФД та його оптимальну позицію в артерії [9].…”
Section: вступunclassified