Clinical performances of a new mode switch function based on a statistical analysis of the atrial rhythm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0
1

Year Published

2001
2001
2011
2011

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(18 citation statements)
references
References 7 publications
0
17
0
1
Order By: Relevance
“…The sensitivity and specificity of the AMS function of the Chorum and Talent were recently reported in 194 patients. 19 All patients underwent 24-hour ECG recording with simultaneous activation of the event recording counters. Based on the documented atrial tachyarrhythmias on the Holter in 23 patients, AMS exhibited a sensitivity of 96%.…”
Section: Clinical Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sensitivity and specificity of the AMS function of the Chorum and Talent were recently reported in 194 patients. 19 All patients underwent 24-hour ECG recording with simultaneous activation of the event recording counters. Based on the documented atrial tachyarrhythmias on the Holter in 23 patients, AMS exhibited a sensitivity of 96%.…”
Section: Clinical Resultsmentioning
confidence: 99%
“…AMS function in the Chorum and Talent DR pacemakers (ELA Medical, Montrouge, France) combines an initial UR switch at the onset of atrial tachyarrhythmias, followed by AMS based on the detection of a sustained atrial rate above a preset atrial tachyarrhythmias detection rate. 18,19 The atrial tachyarrhythmia detection interval is termed the "diagnosis of atrial rhythm acceleration period." This varies from 62.5% (for sinus rate # 80 beats/min) to 75% of the preceding PP interval (for sinus rate .…”
Section: Ela Medical Algorithmsmentioning
confidence: 99%
“…Table 1. So ist der Mode-Switch für "28 aus 32" (Ela Talent [17]) langsamer, aber spezifischer als ein "4-aus-7-" (Medtronic Kappa 700 [21]) oder "5-aus-8-" (Biotronik Inos [22]) Kriterium. Hierbei wird der Zähler bei Detektion einer normalen atrialen Zykluslänge nur um 1 zurückgesetzt.…”
Section: Prinzipien Verschiedener Mode-switch-algorithmenunclassified
“…There are potential compromises between sensitivity and specificity with these algorithms, the balance of which may determine the frequency of arrhythmia-related symptoms. Atrial-based pacing is associated with a risk of developing atrial fibrillation lower than ventricular-based pacing for patients with sinus node dysfunction [22][23][24][25].…”
Section: Introductionmentioning
confidence: 99%