2022
DOI: 10.1111/tan.14781
|View full text |Cite
|
Sign up to set email alerts
|

Clinical utility of serial serum dilutions for HLA antibody interpretation

Abstract: Luminex single antigen bead (SAB) testing has increased the sensitivity and specificity of accurately identifying HLA antibodies, in support of all organ transplantation. However, as described in manufacturers' recommendation, the output of the assay, using mean fluorescence intensity (MFI) units, is only semi‐quantitative. Therefore, the ability to use MFI values to compare between different assays, to accurately guide clinical practice, or be used as an endpoint measure in clinical trials, is limited. To imp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0
4

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 24 publications
0
11
0
4
Order By: Relevance
“…Although the term 'prozone' is often used to describe these inhibitions within the literature, this is an erroneous use of the term in this setting, and its use often causes confusion (Tambur & Schinstock, 2022). Prozone refers to agglutination / precipitation assays to describe a zone in which reactions do not happen.…”
Section: Rationalementioning
confidence: 99%
See 3 more Smart Citations
“…Although the term 'prozone' is often used to describe these inhibitions within the literature, this is an erroneous use of the term in this setting, and its use often causes confusion (Tambur & Schinstock, 2022). Prozone refers to agglutination / precipitation assays to describe a zone in which reactions do not happen.…”
Section: Rationalementioning
confidence: 99%
“…The presence of inhibitory factors which negatively impacts the accurate determination of HLA antibody by SAB assays, have been widely reported in the literature (Tambur & Schinstock, 2022). Such inhibitory factors reported include presence of IgM antibodies (Kosmoliaptsis et al., 2009), high concentration HLA IgG (Tambur & Schinstock, 2022) and complement components (Schnaidt et al., 2011; Schwaiger et al., 2014; Weinstock & Schnaidt, 2013), the result of these reported inhibitions being a negative result or falsely low MFI readout. Although the term ‘prozone’ is often used to describe these inhibitions within the literature, this is an erroneous use of the term in this setting, and its use often causes confusion (Tambur & Schinstock, 2022).…”
Section: | Pre‐transplant Testingmentioning
confidence: 99%
See 2 more Smart Citations
“…Falsch-negative Ergebnisse durch Inhibitoren oder durch das "Prozonenphänomen", die für Seren mit einer hohen Konzentration an HLA-Antikörpern beschrieben sind, lassen sich durch Vorbehandlung der Seren mit Ethylendiamintetraazetat (EDTA) oder Hitzeinaktivierung oder durch die Verdünnung des Serums umgehen [14][15][16]. In hochtitrigen Patientenseren mit abgesättigten Beads kann nur durch Verdünnungsreihen die eigentliche Stärke einzelner Antikörper herausgearbeitet werden, die im unverdünnten Serum vergleichbar hohe Werte für die Fluoreszenzintensität (MFI) haben [17].…”
Section: Lymphozytotoxizitätstest (Lct)unclassified